Approaching the Lower Temporal Limit of Laser-Produced Plasma Sources for Table-Top Soft X-ray NEXAFS Measurements

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Nimlos, Danika, Arellano, Alejandro, Cushing, Scott Kevin
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912025422069760
author Nimlos, Danika
Arellano, Alejandro
Cushing, Scott Kevin
author_facet Nimlos, Danika
Arellano, Alejandro
Cushing, Scott Kevin
contents The increasing popularity of time-resolved X-ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table-top sources for pulsed X-rays. We report on a table top laser-produced plasma (LPP) source that can perform soft X-ray (SXR), near edge X-ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer-pulse-duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate and an implemented self-referencing scheme still allowed for high-resolution, synchrotron-like NEXAFS measurements of Si3N4 and TiO2 thin films with 2.5 minute acquisition times. It was observed that degradation of the gas jet nozzle led to long-term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time-resolved X-ray absorption measurements using table-top laser-produced plasma sources
format Preprint
id arxiv_https___arxiv_org_abs_2409_02280
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Approaching the Lower Temporal Limit of Laser-Produced Plasma Sources for Table-Top Soft X-ray NEXAFS Measurements
Nimlos, Danika
Arellano, Alejandro
Cushing, Scott Kevin
Instrumentation and Detectors
Chemical Physics
Plasma Physics
The increasing popularity of time-resolved X-ray absorption measurements for understanding dynamics in molecular and material systems has led to many advances in table-top sources for pulsed X-rays. We report on a table top laser-produced plasma (LPP) source that can perform soft X-ray (SXR), near edge X-ray absorption fine structure (NEXAFS) measurements using a laser source with 23 ps pulse duration. The spectrometer's key specifications, such as brilliance, resolution, and stability, are characterized against the more commonly used longer-pulse-duration LPP sources. The 23 ps laser produced approximately an order of magnitude weaker SXR flux than the 8 ns laser for a higher power density due to the smaller total energy absorbed by the plasma. The increased repetition rate and an implemented self-referencing scheme still allowed for high-resolution, synchrotron-like NEXAFS measurements of Si3N4 and TiO2 thin films with 2.5 minute acquisition times. It was observed that degradation of the gas jet nozzle led to long-term instability of the source, which can be remediated using alternative nozzle designs. This work demonstrates the feasibility of achieving higher temporal resolution in future time-resolved X-ray absorption measurements using table-top laser-produced plasma sources
title Approaching the Lower Temporal Limit of Laser-Produced Plasma Sources for Table-Top Soft X-ray NEXAFS Measurements
topic Instrumentation and Detectors
Chemical Physics
Plasma Physics
url https://arxiv.org/abs/2409.02280