Thermometry Based on a Superconducting Qubit

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lvov, Dmitrii S., Lemziakov, Sergei A., Ankerhold, Elias, Peltonen, Joonas T., Pekola, Jukka P.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918039593680896
author Lvov, Dmitrii S.
Lemziakov, Sergei A.
Ankerhold, Elias
Peltonen, Joonas T.
Pekola, Jukka P.
author_facet Lvov, Dmitrii S.
Lemziakov, Sergei A.
Ankerhold, Elias
Peltonen, Joonas T.
Pekola, Jukka P.
contents We report temperature measurements using a transmon qubit by detecting the population of its first three energy levels, after applying a sequence of $π$-pulses and performing projective dispersive readout. We measure the effective temperature of the qubit and characterize its relaxation and coherence times $τ_{1,2}$ for three devices in the temperature range of $20-300$ mK. We analyze the process of qubit thermalization to its effective environment consisting of multiple heat baths and support it with experimental data. Signal-to-noise (SNR) ratio of the temperature measurement depends strongly on $τ_1$, which drops at higher temperatures due to quasiparticle excitations, adversely affecting the measurements and setting an upper bound of the dynamic temperature range of the thermometer. The measurement relies on coherent dynamics of the qubit during the $π$-pulses. The effective qubit temperature follows closely that of the cryostat in the range of $100 - 250$ mK. We present a numerical model of the qubit population distribution and compare it favorably with the experimental results. Finally, we compare our technique with previous works on qubit thermometry and discuss its application prospects.
format Preprint
id arxiv_https___arxiv_org_abs_2409_02784
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Thermometry Based on a Superconducting Qubit
Lvov, Dmitrii S.
Lemziakov, Sergei A.
Ankerhold, Elias
Peltonen, Joonas T.
Pekola, Jukka P.
Quantum Physics
We report temperature measurements using a transmon qubit by detecting the population of its first three energy levels, after applying a sequence of $π$-pulses and performing projective dispersive readout. We measure the effective temperature of the qubit and characterize its relaxation and coherence times $τ_{1,2}$ for three devices in the temperature range of $20-300$ mK. We analyze the process of qubit thermalization to its effective environment consisting of multiple heat baths and support it with experimental data. Signal-to-noise (SNR) ratio of the temperature measurement depends strongly on $τ_1$, which drops at higher temperatures due to quasiparticle excitations, adversely affecting the measurements and setting an upper bound of the dynamic temperature range of the thermometer. The measurement relies on coherent dynamics of the qubit during the $π$-pulses. The effective qubit temperature follows closely that of the cryostat in the range of $100 - 250$ mK. We present a numerical model of the qubit population distribution and compare it favorably with the experimental results. Finally, we compare our technique with previous works on qubit thermometry and discuss its application prospects.
title Thermometry Based on a Superconducting Qubit
topic Quantum Physics
url https://arxiv.org/abs/2409.02784