Magnetic field tunable spectral response of kinetic inductance detectors

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Levy-Bertrand, F., Calvo, M., Chowdhury, U., Gomez, A., Goupy, J., Monfardini, A.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917903898509312
author Levy-Bertrand, F.
Calvo, M.
Chowdhury, U.
Gomez, A.
Goupy, J.
Monfardini, A.
author_facet Levy-Bertrand, F.
Calvo, M.
Chowdhury, U.
Gomez, A.
Goupy, J.
Monfardini, A.
contents We tune the onset of optical response in aluminium kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in spectral response is due to the decrease of the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysteretically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.
format Preprint
id arxiv_https___arxiv_org_abs_2409_03356
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Magnetic field tunable spectral response of kinetic inductance detectors
Levy-Bertrand, F.
Calvo, M.
Chowdhury, U.
Gomez, A.
Goupy, J.
Monfardini, A.
Superconductivity
Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
We tune the onset of optical response in aluminium kinetic inductance detectors from a natural cutoff frequency of 90 GHz to 60 GHz by applying an external magnetic field. The change in spectral response is due to the decrease of the superconducting gap, from 90 GHz at zero magnetic field to 60 GHz at a magnetic field of around 3 mT. We characterize the variation of the superconducting gap, the detector frequency shift and the internal quality factor as a function of the applied field. In principle, the magnetic field tunable response could be used to make spectroscopic measurements. In practice, the internal quality factor behaves hysteretically with the magnetic field due to the presence of vortices in the thin superconducting film. We conclude by discussing possible solutions to achieve spectroscopy measurements using kinetic inductance detectors and magnetic field.
title Magnetic field tunable spectral response of kinetic inductance detectors
topic Superconductivity
Instrumentation and Methods for Astrophysics
Instrumentation and Detectors
url https://arxiv.org/abs/2409.03356