Influence of Early through Late Fusion on Pancreas Segmentation from Imperfectly Registered Multimodal MRI

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Remedios, Lucas W., Liu, Han, Remedios, Samuel W., Zuo, Lianrui, Saunders, Adam M., Bao, Shunxing, Huo, Yuankai, Powers, Alvin C., Virostko, John, Landman, Bennett A.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912018074697728
author Remedios, Lucas W.
Liu, Han
Remedios, Samuel W.
Zuo, Lianrui
Saunders, Adam M.
Bao, Shunxing
Huo, Yuankai
Powers, Alvin C.
Virostko, John
Landman, Bennett A.
author_facet Remedios, Lucas W.
Liu, Han
Remedios, Samuel W.
Zuo, Lianrui
Saunders, Adam M.
Bao, Shunxing
Huo, Yuankai
Powers, Alvin C.
Virostko, John
Landman, Bennett A.
contents Multimodal fusion promises better pancreas segmentation. However, where to perform fusion in models is still an open question. It is unclear if there is a best location to fuse information when analyzing pairs of imperfectly aligned images. Two main alignment challenges in this pancreas segmentation study are 1) the pancreas is deformable and 2) breathing deforms the abdomen. Even after image registration, relevant deformations are often not corrected. We examine how early through late fusion impacts pancreas segmentation. We used 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas labels. We used image registration (deeds) to align the image pairs. We trained a collection of basic UNets with different fusion points, spanning from early to late, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. We assessed generalization of fusion points on nnUNet. The single-modality T2w baseline using a basic UNet model had a Dice score of 0.73, while the same baseline on the nnUNet model achieved 0.80. For the basic UNet, the best fusion approach occurred in the middle of the encoder (early/mid fusion), which led to a statistically significant improvement of 0.0125 on Dice score compared to the baseline. For the nnUNet, the best fusion approach was naïve image concatenation before the model (early fusion), which resulted in a statistically significant Dice score increase of 0.0021 compared to baseline. Fusion in specific blocks can improve performance, but the best blocks for fusion are model specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs.
format Preprint
id arxiv_https___arxiv_org_abs_2409_04563
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Influence of Early through Late Fusion on Pancreas Segmentation from Imperfectly Registered Multimodal MRI
Remedios, Lucas W.
Liu, Han
Remedios, Samuel W.
Zuo, Lianrui
Saunders, Adam M.
Bao, Shunxing
Huo, Yuankai
Powers, Alvin C.
Virostko, John
Landman, Bennett A.
Computer Vision and Pattern Recognition
Multimodal fusion promises better pancreas segmentation. However, where to perform fusion in models is still an open question. It is unclear if there is a best location to fuse information when analyzing pairs of imperfectly aligned images. Two main alignment challenges in this pancreas segmentation study are 1) the pancreas is deformable and 2) breathing deforms the abdomen. Even after image registration, relevant deformations are often not corrected. We examine how early through late fusion impacts pancreas segmentation. We used 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas labels. We used image registration (deeds) to align the image pairs. We trained a collection of basic UNets with different fusion points, spanning from early to late, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. We assessed generalization of fusion points on nnUNet. The single-modality T2w baseline using a basic UNet model had a Dice score of 0.73, while the same baseline on the nnUNet model achieved 0.80. For the basic UNet, the best fusion approach occurred in the middle of the encoder (early/mid fusion), which led to a statistically significant improvement of 0.0125 on Dice score compared to the baseline. For the nnUNet, the best fusion approach was naïve image concatenation before the model (early fusion), which resulted in a statistically significant Dice score increase of 0.0021 compared to baseline. Fusion in specific blocks can improve performance, but the best blocks for fusion are model specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs.
title Influence of Early through Late Fusion on Pancreas Segmentation from Imperfectly Registered Multimodal MRI
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2409.04563