System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Vaccaro, Davide, van der Kuur, Jan, van der Hulst, Paul, Vos, Tobias, de Wit, Martin, Gottardi, Luciano, Ravensberg, Kevin, Taralli, Emanuele, Adams, Joseph, Bandler, Simon, Bennet, Douglas, Chervenak, James, Doriese, Bertrand, Durkin, Malcolm, Gard, Johnathon, Reintsema, Carl, Sakai, Kazuhiro, Smith, Steven, Ullom, Joel, Wakeham, Nicholas, Herder, Jan-Willem den, jackson, Brian, Khosropanah, Pourya, Gao, Jian-Rong, Roelfsema, Peter, Simionescu, Aurora
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916599620960256
author Vaccaro, Davide
van der Kuur, Jan
van der Hulst, Paul
Vos, Tobias
de Wit, Martin
Gottardi, Luciano
Ravensberg, Kevin
Taralli, Emanuele
Adams, Joseph
Bandler, Simon
Bennet, Douglas
Chervenak, James
Doriese, Bertrand
Durkin, Malcolm
Gard, Johnathon
Reintsema, Carl
Sakai, Kazuhiro
Smith, Steven
Ullom, Joel
Wakeham, Nicholas
Herder, Jan-Willem den
jackson, Brian
Khosropanah, Pourya
Gao, Jian-Rong
Roelfsema, Peter
Simionescu, Aurora
author_facet Vaccaro, Davide
van der Kuur, Jan
van der Hulst, Paul
Vos, Tobias
de Wit, Martin
Gottardi, Luciano
Ravensberg, Kevin
Taralli, Emanuele
Adams, Joseph
Bandler, Simon
Bennet, Douglas
Chervenak, James
Doriese, Bertrand
Durkin, Malcolm
Gard, Johnathon
Reintsema, Carl
Sakai, Kazuhiro
Smith, Steven
Ullom, Joel
Wakeham, Nicholas
Herder, Jan-Willem den
jackson, Brian
Khosropanah, Pourya
Gao, Jian-Rong
Roelfsema, Peter
Simionescu, Aurora
contents The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of about 1500 transition-edge sensors (TES) read out via SQUID time-division multiplexing (TDM). A TDM-based laboratory test-bed has been assembled at SRON, hosting an array of $75\times 75\ \upmu$m$^2$ TESs that are read out via 2-column $\times$ 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test-bed, whose harness has a length close to what envisioned for X-IFU, which allowed to achieve a co-added energy resolution at a level of 2.7~eV FWHM at 6~keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU Focal-Plane Assembly Development Model.
format Preprint
id arxiv_https___arxiv_org_abs_2409_05643
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU
Vaccaro, Davide
van der Kuur, Jan
van der Hulst, Paul
Vos, Tobias
de Wit, Martin
Gottardi, Luciano
Ravensberg, Kevin
Taralli, Emanuele
Adams, Joseph
Bandler, Simon
Bennet, Douglas
Chervenak, James
Doriese, Bertrand
Durkin, Malcolm
Gard, Johnathon
Reintsema, Carl
Sakai, Kazuhiro
Smith, Steven
Ullom, Joel
Wakeham, Nicholas
Herder, Jan-Willem den
jackson, Brian
Khosropanah, Pourya
Gao, Jian-Rong
Roelfsema, Peter
Simionescu, Aurora
Instrumentation and Methods for Astrophysics
The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution ($<$ 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of about 1500 transition-edge sensors (TES) read out via SQUID time-division multiplexing (TDM). A TDM-based laboratory test-bed has been assembled at SRON, hosting an array of $75\times 75\ \upmu$m$^2$ TESs that are read out via 2-column $\times$ 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test-bed, whose harness has a length close to what envisioned for X-IFU, which allowed to achieve a co-added energy resolution at a level of 2.7~eV FWHM at 6~keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU Focal-Plane Assembly Development Model.
title System performance of a cryogenic test-bed for the time-division multiplexing readout for NewAthena X-IFU
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2409.05643