OpenDosimeter: Open Hardware Personal X-ray Dosimeter

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Ger, Norah, Ku, Alice, Lopez, Jasmyn, Bennett, N. Robert, Wang, Jia, Ateka, Grace, Anyenda, Enoch, Rosezky, Matthias, Kilavi, Pamela, Wang, Adam S., Shaker, Kian
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917137604411392
author Ger, Norah
Ku, Alice
Lopez, Jasmyn
Bennett, N. Robert
Wang, Jia
Ateka, Grace
Anyenda, Enoch
Rosezky, Matthias
Kilavi, Pamela
Wang, Adam S.
Shaker, Kian
author_facet Ger, Norah
Ku, Alice
Lopez, Jasmyn
Bennett, N. Robert
Wang, Jia
Ateka, Grace
Anyenda, Enoch
Rosezky, Matthias
Kilavi, Pamela
Wang, Adam S.
Shaker, Kian
contents We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at $\pm$25% accuracy, tested for energies up to 120 keV. The maximum dose rate readings are limited by pile-up effects when approaching count rate saturation ($\sim$77 kcps at $\sim$13 $μ$s average pulse processing time). The total component cost for making an OpenDosimeter is <\$100, which, combined with its open design (both hardware and software), enables cost-effective local reproducibility on a global scale. Through a student workshop, we also demonstrate its effectiveness as an educational and capacity-building tool. This paper complements the open-source documentation by explaining the underlying technology, the algorithm for dose calculation, and areas for future improvement.
format Preprint
id arxiv_https___arxiv_org_abs_2409_09993
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle OpenDosimeter: Open Hardware Personal X-ray Dosimeter
Ger, Norah
Ku, Alice
Lopez, Jasmyn
Bennett, N. Robert
Wang, Jia
Ateka, Grace
Anyenda, Enoch
Rosezky, Matthias
Kilavi, Pamela
Wang, Adam S.
Shaker, Kian
Instrumentation and Detectors
Medical Physics
We present OpenDosimeter (www.opendosimeter.org), an open hardware solution for real-time personal X-ray dose monitoring based on a scintillation counter. Using an X-ray sensor assembly (LYSO + SiPM) on a custom board powered by a Raspberry Pi Pico, OpenDosimeter provides real-time feedback (1 Hz), data logging (10 hours), and battery-powered operation. One of the core innovations is that we calibrate the device using $^{241}$Am found in ionization smoke detectors. Specifically, we use the $γ$-emissions to spectrally calibrate the dosimeter, then calculate the effective dose from X-ray exposure by compensating for the scintillator absorption efficiency and applying energy-to-dose coefficients derived from tabulated data in the ICRP 116 publication. We demonstrate that this transparent approach enables real-time dose rate readings with a linear response between 0.1-1000 $μ$Sv/h at $\pm$25% accuracy, tested for energies up to 120 keV. The maximum dose rate readings are limited by pile-up effects when approaching count rate saturation ($\sim$77 kcps at $\sim$13 $μ$s average pulse processing time). The total component cost for making an OpenDosimeter is <\$100, which, combined with its open design (both hardware and software), enables cost-effective local reproducibility on a global scale. Through a student workshop, we also demonstrate its effectiveness as an educational and capacity-building tool. This paper complements the open-source documentation by explaining the underlying technology, the algorithm for dose calculation, and areas for future improvement.
title OpenDosimeter: Open Hardware Personal X-ray Dosimeter
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2409.09993