Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging via Self-supervision

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Xie, Huidong, Guo, Liang, Velo, Alexandre, Liu, Zhao, Liu, Qiong, Guo, Xueqi, Zhou, Bo, Chen, Xiongchao, Tsai, Yu-Jung, Miao, Tianshun, Xia, Menghua, Liu, Yi-Hwa, Armstrong, Ian S., Wang, Ge, Carson, Richard E., Sinusas, Albert J., Liu, Chi
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912033298972672
author Xie, Huidong
Guo, Liang
Velo, Alexandre
Liu, Zhao
Liu, Qiong
Guo, Xueqi
Zhou, Bo
Chen, Xiongchao
Tsai, Yu-Jung
Miao, Tianshun
Xia, Menghua
Liu, Yi-Hwa
Armstrong, Ian S.
Wang, Ge
Carson, Richard E.
Sinusas, Albert J.
Liu, Chi
author_facet Xie, Huidong
Guo, Liang
Velo, Alexandre
Liu, Zhao
Liu, Qiong
Guo, Xueqi
Zhou, Bo
Chen, Xiongchao
Tsai, Yu-Jung
Miao, Tianshun
Xia, Menghua
Liu, Yi-Hwa
Armstrong, Ian S.
Wang, Ge
Carson, Richard E.
Sinusas, Albert J.
Liu, Chi
contents Rb-82 is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of 82-Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short half-life of 82-Rb results in noisy dynamic frames. Low signal-to-noise ratio would result in inaccurate and biased image quantification. Noisy dynamic frames also lead to highly noisy parametric images. The noise levels also vary substantially in different dynamic frames due to radiotracer decay and short half-life. Existing denoising methods are not applicable for this task due to the lack of paired training inputs/labels and inability to generalize across varying noise levels. Second, 82-Rb emits high-energy positrons. Compared with other tracers such as 18-F, 82-Rb travels a longer distance before annihilation, which negatively affect image spatial resolution. Here, the goal of this study is to propose a self-supervised method for simultaneous (1) noise-aware dynamic image denoising and (2) positron range correction for 82-Rb cardiac PET imaging. Tested on a series of PET scans from a cohort of normal volunteers, the proposed method produced images with superior visual quality. To demonstrate the improvement in image quantification, we compared image-derived input functions (IDIFs) with arterial input functions (AIFs) from continuous arterial blood samples. The IDIF derived from the proposed method led to lower AUC differences, decreasing from 11.09% to 7.58% on average, compared to the original dynamic frames. The proposed method also improved the quantification of myocardium blood flow (MBF), as validated against 15-O-water scans, with mean MBF differences decreased from 0.43 to 0.09, compared to the original dynamic frames. We also conducted a generalizability experiment on 37 patient scans obtained from a different country using a different scanner.
format Preprint
id arxiv_https___arxiv_org_abs_2409_11543
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging via Self-supervision
Xie, Huidong
Guo, Liang
Velo, Alexandre
Liu, Zhao
Liu, Qiong
Guo, Xueqi
Zhou, Bo
Chen, Xiongchao
Tsai, Yu-Jung
Miao, Tianshun
Xia, Menghua
Liu, Yi-Hwa
Armstrong, Ian S.
Wang, Ge
Carson, Richard E.
Sinusas, Albert J.
Liu, Chi
Image and Video Processing
Rb-82 is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of 82-Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short half-life of 82-Rb results in noisy dynamic frames. Low signal-to-noise ratio would result in inaccurate and biased image quantification. Noisy dynamic frames also lead to highly noisy parametric images. The noise levels also vary substantially in different dynamic frames due to radiotracer decay and short half-life. Existing denoising methods are not applicable for this task due to the lack of paired training inputs/labels and inability to generalize across varying noise levels. Second, 82-Rb emits high-energy positrons. Compared with other tracers such as 18-F, 82-Rb travels a longer distance before annihilation, which negatively affect image spatial resolution. Here, the goal of this study is to propose a self-supervised method for simultaneous (1) noise-aware dynamic image denoising and (2) positron range correction for 82-Rb cardiac PET imaging. Tested on a series of PET scans from a cohort of normal volunteers, the proposed method produced images with superior visual quality. To demonstrate the improvement in image quantification, we compared image-derived input functions (IDIFs) with arterial input functions (AIFs) from continuous arterial blood samples. The IDIF derived from the proposed method led to lower AUC differences, decreasing from 11.09% to 7.58% on average, compared to the original dynamic frames. The proposed method also improved the quantification of myocardium blood flow (MBF), as validated against 15-O-water scans, with mean MBF differences decreased from 0.43 to 0.09, compared to the original dynamic frames. We also conducted a generalizability experiment on 37 patient scans obtained from a different country using a different scanner.
title Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging via Self-supervision
topic Image and Video Processing
url https://arxiv.org/abs/2409.11543