Modeling water radiolysis with Geant4-DNA: Impact of the temporal structure of the irradiation pulse under oxygen conditions

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Le, Tuan Anh, Tran, Hoang Ngoc, Fattori, Serena, Phan, Viet Cuong, Incerti, Sebastien
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909319147028480
author Le, Tuan Anh
Tran, Hoang Ngoc
Fattori, Serena
Phan, Viet Cuong
Incerti, Sebastien
author_facet Le, Tuan Anh
Tran, Hoang Ngoc
Fattori, Serena
Phan, Viet Cuong
Incerti, Sebastien
contents The differences in H2O2 production between conventional (CONV) and ultra-high dose rate (UHDR) irradiations in water radiolysis are still not fully understood. The lower levels of this radiolytic species, as a critical end product of water radiolysis, are particularly relevant for investigating the connection between the high-density energy deposition during short-duration physical events (ionizations or excitations) and biological responses of the FLASH effect. In this study, we developed a new Geant4-DNA chemistry model to simulate radiolysis considering the time structure of the irradiation pulse at different absorbed doses to liquid water of 0.01, 0.1, 1, and 2 Gy under 1 MeV electron irradiation. The model allows the description of the beam's temporal structure, including the pulse duration, the pulse repetition frequency, and the pulse amplitude for the different beam irradiation conditions through a wide dose rate range, from 0.01 Gy/s up to about 105 Gy/s, at various oxygen concentrations. The preliminary results indicate a correlation between the temporal structure of the pulses and a significant reduction in the production of reactive oxygen species (ROS) at different dose rates.
format Preprint
id arxiv_https___arxiv_org_abs_2409_11993
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Modeling water radiolysis with Geant4-DNA: Impact of the temporal structure of the irradiation pulse under oxygen conditions
Le, Tuan Anh
Tran, Hoang Ngoc
Fattori, Serena
Phan, Viet Cuong
Incerti, Sebastien
Chemical Physics
Computational Physics
Medical Physics
The differences in H2O2 production between conventional (CONV) and ultra-high dose rate (UHDR) irradiations in water radiolysis are still not fully understood. The lower levels of this radiolytic species, as a critical end product of water radiolysis, are particularly relevant for investigating the connection between the high-density energy deposition during short-duration physical events (ionizations or excitations) and biological responses of the FLASH effect. In this study, we developed a new Geant4-DNA chemistry model to simulate radiolysis considering the time structure of the irradiation pulse at different absorbed doses to liquid water of 0.01, 0.1, 1, and 2 Gy under 1 MeV electron irradiation. The model allows the description of the beam's temporal structure, including the pulse duration, the pulse repetition frequency, and the pulse amplitude for the different beam irradiation conditions through a wide dose rate range, from 0.01 Gy/s up to about 105 Gy/s, at various oxygen concentrations. The preliminary results indicate a correlation between the temporal structure of the pulses and a significant reduction in the production of reactive oxygen species (ROS) at different dose rates.
title Modeling water radiolysis with Geant4-DNA: Impact of the temporal structure of the irradiation pulse under oxygen conditions
topic Chemical Physics
Computational Physics
Medical Physics
url https://arxiv.org/abs/2409.11993