The Effects of Instrumental Deadtime on NICER Timing Products

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Webbe, Robbie, Young, A. J.
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912850283331584
author Webbe, Robbie
Young, A. J.
author_facet Webbe, Robbie
Young, A. J.
contents The X-ray Timing Instrument as part of the Neutron Star Interior Composition Explorer has the potential to examine the time-domain properties of compact objects in regimes not explored by previous timing instruments, due to its combination of high effective area and timing resolution. We consider the effects of instrumental deadtime at a range of effective countrates in a series of observations of the X-ray binary GX 339-4 to determine what effect deadtime has on photometric and Fourier frequency-domain products. We find that there are no significant inconsistencies across the functional detectors in the instrument, and that in the regimes where instrumental deadtime is a limiting factor on observations that previous approaches to dealing with deadtime, as applied to RXTE and other detectors, are still appropriate, and that performing deadtime corrections to lightcurves before creating Fourier products are not necessary at the count rates considered in our analysis.
format Preprint
id arxiv_https___arxiv_org_abs_2409_12574
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle The Effects of Instrumental Deadtime on NICER Timing Products
Webbe, Robbie
Young, A. J.
Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
The X-ray Timing Instrument as part of the Neutron Star Interior Composition Explorer has the potential to examine the time-domain properties of compact objects in regimes not explored by previous timing instruments, due to its combination of high effective area and timing resolution. We consider the effects of instrumental deadtime at a range of effective countrates in a series of observations of the X-ray binary GX 339-4 to determine what effect deadtime has on photometric and Fourier frequency-domain products. We find that there are no significant inconsistencies across the functional detectors in the instrument, and that in the regimes where instrumental deadtime is a limiting factor on observations that previous approaches to dealing with deadtime, as applied to RXTE and other detectors, are still appropriate, and that performing deadtime corrections to lightcurves before creating Fourier products are not necessary at the count rates considered in our analysis.
title The Effects of Instrumental Deadtime on NICER Timing Products
topic Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
url https://arxiv.org/abs/2409.12574