Saved in:
Bibliographic Details
Main Authors: Flores-Araiza, Daniel, Lopez-Tiro, Francisco, Larose, Clément, Hinojosa, Salvador, Mendez-Vazquez, Andres, Gonzalez-Mendoza, Miguel, Ochoa-Ruiz, Gilberto, Daul, Christian
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2409.12883
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914952825012224
author Flores-Araiza, Daniel
Lopez-Tiro, Francisco
Larose, Clément
Hinojosa, Salvador
Mendez-Vazquez, Andres
Gonzalez-Mendoza, Miguel
Ochoa-Ruiz, Gilberto
Daul, Christian
author_facet Flores-Araiza, Daniel
Lopez-Tiro, Francisco
Larose, Clément
Hinojosa, Salvador
Mendez-Vazquez, Andres
Gonzalez-Mendoza, Miguel
Ochoa-Ruiz, Gilberto
Daul, Christian
contents The in-vivo identification of the kidney stone types during an ureteroscopy would be a major medical advance in urology, as it could reduce the time of the tedious renal calculi extraction process, while diminishing infection risks. Furthermore, such an automated procedure would make possible to prescribe anti-recurrence treatments immediately. Nowadays, only few experienced urologists are able to recognize the kidney stone types in the images of the videos displayed on a screen during the endoscopy. Thus, several deep learning (DL) models have recently been proposed to automatically recognize the kidney stone types using ureteroscopic images. However, these DL models are of black box nature whicl limits their applicability in clinical settings. This contribution proposes a case-based reasoning DL model which uses prototypical parts (PPs) and generates local and global descriptors. The PPs encode for each class (i.e., kidney stone type) visual feature information (hue, saturation, intensity and textures) similar to that used by biologists. The PPs are optimally generated due a new loss function used during the model training. Moreover, the local and global descriptors of PPs allow to explain the decisions ("what" information, "where in the images") in an understandable way for biologists and urologists. The proposed DL model has been tested on a database including images of the six most widespread kidney stone types. The overall average classification accuracy was 90.37. When comparing this results with that of the eight other DL models of the kidney stone state-of-the-art, it can be seen that the valuable gain in explanability was not reached at the expense of accuracy which was even slightly increased with respect to that (88.2) of the best method of the literature. These promising and interpretable results also encourage urologists to put their trust in AI-based solutions.
format Preprint
id arxiv_https___arxiv_org_abs_2409_12883
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Improving Prototypical Parts Abstraction for Case-Based Reasoning Explanations Designed for the Kidney Stone Type Recognition
Flores-Araiza, Daniel
Lopez-Tiro, Francisco
Larose, Clément
Hinojosa, Salvador
Mendez-Vazquez, Andres
Gonzalez-Mendoza, Miguel
Ochoa-Ruiz, Gilberto
Daul, Christian
Computer Vision and Pattern Recognition
Artificial Intelligence
The in-vivo identification of the kidney stone types during an ureteroscopy would be a major medical advance in urology, as it could reduce the time of the tedious renal calculi extraction process, while diminishing infection risks. Furthermore, such an automated procedure would make possible to prescribe anti-recurrence treatments immediately. Nowadays, only few experienced urologists are able to recognize the kidney stone types in the images of the videos displayed on a screen during the endoscopy. Thus, several deep learning (DL) models have recently been proposed to automatically recognize the kidney stone types using ureteroscopic images. However, these DL models are of black box nature whicl limits their applicability in clinical settings. This contribution proposes a case-based reasoning DL model which uses prototypical parts (PPs) and generates local and global descriptors. The PPs encode for each class (i.e., kidney stone type) visual feature information (hue, saturation, intensity and textures) similar to that used by biologists. The PPs are optimally generated due a new loss function used during the model training. Moreover, the local and global descriptors of PPs allow to explain the decisions ("what" information, "where in the images") in an understandable way for biologists and urologists. The proposed DL model has been tested on a database including images of the six most widespread kidney stone types. The overall average classification accuracy was 90.37. When comparing this results with that of the eight other DL models of the kidney stone state-of-the-art, it can be seen that the valuable gain in explanability was not reached at the expense of accuracy which was even slightly increased with respect to that (88.2) of the best method of the literature. These promising and interpretable results also encourage urologists to put their trust in AI-based solutions.
title Improving Prototypical Parts Abstraction for Case-Based Reasoning Explanations Designed for the Kidney Stone Type Recognition
topic Computer Vision and Pattern Recognition
Artificial Intelligence
url https://arxiv.org/abs/2409.12883