High-contrast imager for complex aperture telescopes (HiCAT): 11. System-level demonstration of the Apodized Pupil Lyot Coronagraph with a segmented aperture in air
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2024
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866912035234643968 |
|---|---|
| author | Soummer, Rémi Pourcelot, Raphaël Por, Emiel H. Steiger, Sarah Laginja, Iva Buralli, Benjamin Redmond, Susan Pueyo, Laurent Perrin, Marshall D. Ferrari, Marc Fowler, Jules Hagopian, John N'Diaye, Mamadou Nguyen, Meiji Nickson, Bryony Petrone, Peter Sahoo, Ananya Sivaramakrishnan, Anand Will, Scott D. |
| author_facet | Soummer, Rémi Pourcelot, Raphaël Por, Emiel H. Steiger, Sarah Laginja, Iva Buralli, Benjamin Redmond, Susan Pueyo, Laurent Perrin, Marshall D. Ferrari, Marc Fowler, Jules Hagopian, John N'Diaye, Mamadou Nguyen, Meiji Nickson, Bryony Petrone, Peter Sahoo, Ananya Sivaramakrishnan, Anand Will, Scott D. |
| contents | We present the final results of the Apodized Pupil Lyot Coronagraph (APLC) on the High-contrast imager for Complex Aperture Telescopes (HiCAT) testbed, under NASA's Strategic Astrophysics Technology program. The HiCAT testbed was developed over the past decade to enable a system-level demonstration of coronagraphy for exoplanet direct imaging with the future Habitable Wolds Observatory. HiCAT includes an active, segmented telescope simulator, a coronagraph, and metrology systems (Low-order and Mid-Order Zernike Wavefront Sensors, and Phase Retrieval camera). These results correspond to an off-axis (un-obscured) configuration, as was envisioned in the 2020 Decadal Survey Recommendations. Narrowband and broadband dark holes are generated using two continuous deformable mirrors (DM) to control high order wavefront aberrations, and low-order drifts can be further stabilized using the LOWFS loop. The APLC apodizers, manufactured using carbon nanotubes, were optimized for broadband performance and include the calibrated geometric aperture.
HiCAT is, to this date, the only testbed facility able to demonstrate high-contrast coronagraphy with a truly segmented aperture, as is required for the Habitable World Observatory, albeit limited to ambient conditions. Results presented here include $6\times 10^{-8}$ (90% CI) contrast in 9% bandpass in a 360 deg dark hole with inner and outer working angles of $4.4 λ/D_{pupil}$ and $11 λ/D_{pupil}$ . Narrowband contrast (3% bandpass) reaches $2.4\times 10^{-8}$ (90% confidence interval). |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2409_12931 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | High-contrast imager for complex aperture telescopes (HiCAT): 11. System-level demonstration of the Apodized Pupil Lyot Coronagraph with a segmented aperture in air Soummer, Rémi Pourcelot, Raphaël Por, Emiel H. Steiger, Sarah Laginja, Iva Buralli, Benjamin Redmond, Susan Pueyo, Laurent Perrin, Marshall D. Ferrari, Marc Fowler, Jules Hagopian, John N'Diaye, Mamadou Nguyen, Meiji Nickson, Bryony Petrone, Peter Sahoo, Ananya Sivaramakrishnan, Anand Will, Scott D. Instrumentation and Methods for Astrophysics We present the final results of the Apodized Pupil Lyot Coronagraph (APLC) on the High-contrast imager for Complex Aperture Telescopes (HiCAT) testbed, under NASA's Strategic Astrophysics Technology program. The HiCAT testbed was developed over the past decade to enable a system-level demonstration of coronagraphy for exoplanet direct imaging with the future Habitable Wolds Observatory. HiCAT includes an active, segmented telescope simulator, a coronagraph, and metrology systems (Low-order and Mid-Order Zernike Wavefront Sensors, and Phase Retrieval camera). These results correspond to an off-axis (un-obscured) configuration, as was envisioned in the 2020 Decadal Survey Recommendations. Narrowband and broadband dark holes are generated using two continuous deformable mirrors (DM) to control high order wavefront aberrations, and low-order drifts can be further stabilized using the LOWFS loop. The APLC apodizers, manufactured using carbon nanotubes, were optimized for broadband performance and include the calibrated geometric aperture. HiCAT is, to this date, the only testbed facility able to demonstrate high-contrast coronagraphy with a truly segmented aperture, as is required for the Habitable World Observatory, albeit limited to ambient conditions. Results presented here include $6\times 10^{-8}$ (90% CI) contrast in 9% bandpass in a 360 deg dark hole with inner and outer working angles of $4.4 λ/D_{pupil}$ and $11 λ/D_{pupil}$ . Narrowband contrast (3% bandpass) reaches $2.4\times 10^{-8}$ (90% confidence interval). |
| title | High-contrast imager for complex aperture telescopes (HiCAT): 11. System-level demonstration of the Apodized Pupil Lyot Coronagraph with a segmented aperture in air |
| topic | Instrumentation and Methods for Astrophysics |
| url | https://arxiv.org/abs/2409.12931 |