Ortho-positronium Lifetime For Soft-tissue Classification

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Avachat, Ashish V., Mahmoud, Kholod H., Leja, Anthony G., Xu, Jiajie J., Anastasio, Mark A., Sivaguru, Mayandi, Di Fulvio, Angela
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910613797601280
author Avachat, Ashish V.
Mahmoud, Kholod H.
Leja, Anthony G.
Xu, Jiajie J.
Anastasio, Mark A.
Sivaguru, Mayandi
Di Fulvio, Angela
author_facet Avachat, Ashish V.
Mahmoud, Kholod H.
Leja, Anthony G.
Xu, Jiajie J.
Anastasio, Mark A.
Sivaguru, Mayandi
Di Fulvio, Angela
contents The objective of this work is to showcase the ortho-positronium lifetime as a probe for soft-tissue characterization. We employed positron annihilation lifetime spectroscopy to experimentally measure the three components of the positron annihilation lifetime para-positronium (p-Ps), positron, and ortho-positronium (o-Ps) for three types of porcine, non-fixated soft tissues ex vivo: adipose, hepatic, and muscle.Then, we benchmarked our measurements with X-ray phase-contrast imaging, which is the current state-of-the-art for soft-tissue analysis. We found that the o-Ps lifetime in adipose tissues (2.54+/-0.12) ns was approximately 20\% longer than in hepatic (2.04+/-0.09 ns) and muscle (2.03+/-0.12 ns) tissues .In addition, the separation between the measurements for adipose tissue and the other tissues was better from o-Ps lifetime measurement than from X-ray phase-contrast imaging. This experimental study proved that the o-Ps lifetime is a viable non-invasive probe for characterizing and classifying the different soft tissues. Specifically, o-Ps lifetime as a soft-tissue characterization probe had a strong sensitivity to the lipid content that can be potentially implemented in commercial positron emission tomography scanners that feature list-mode data acquisition.
format Preprint
id arxiv_https___arxiv_org_abs_2409_13102
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Ortho-positronium Lifetime For Soft-tissue Classification
Avachat, Ashish V.
Mahmoud, Kholod H.
Leja, Anthony G.
Xu, Jiajie J.
Anastasio, Mark A.
Sivaguru, Mayandi
Di Fulvio, Angela
Instrumentation and Detectors
The objective of this work is to showcase the ortho-positronium lifetime as a probe for soft-tissue characterization. We employed positron annihilation lifetime spectroscopy to experimentally measure the three components of the positron annihilation lifetime para-positronium (p-Ps), positron, and ortho-positronium (o-Ps) for three types of porcine, non-fixated soft tissues ex vivo: adipose, hepatic, and muscle.Then, we benchmarked our measurements with X-ray phase-contrast imaging, which is the current state-of-the-art for soft-tissue analysis. We found that the o-Ps lifetime in adipose tissues (2.54+/-0.12) ns was approximately 20\% longer than in hepatic (2.04+/-0.09 ns) and muscle (2.03+/-0.12 ns) tissues .In addition, the separation between the measurements for adipose tissue and the other tissues was better from o-Ps lifetime measurement than from X-ray phase-contrast imaging. This experimental study proved that the o-Ps lifetime is a viable non-invasive probe for characterizing and classifying the different soft tissues. Specifically, o-Ps lifetime as a soft-tissue characterization probe had a strong sensitivity to the lipid content that can be potentially implemented in commercial positron emission tomography scanners that feature list-mode data acquisition.
title Ortho-positronium Lifetime For Soft-tissue Classification
topic Instrumentation and Detectors
url https://arxiv.org/abs/2409.13102