Safe Control of Grid-Interfacing Inverters with Current Magnitude Limits

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Joswig-Jones, Trager, Zhang, Baosen
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915208669167616
author Joswig-Jones, Trager
Zhang, Baosen
author_facet Joswig-Jones, Trager
Zhang, Baosen
contents Grid-interfacing inverters allow renewable resources to be connected to the electric grid and offer fast and programmable control responses. However, inverters are subject to significant physical constraints. One such constraint is a current magnitude limit required to protect semiconductor devices. While many current limiting methods are available, they can often unpredictably alter the behavior of the inverter control during overcurrent events leading to instability or poor performance. In this paper, we present a safety filter approach to limit the current magnitude of inverters controlled as voltage sources. The safety filter problem is formulated with a control barrier function constraint that encodes the current magnitude limit. To ensure feasibility of the problem, we prove the existence of a safe linear controller for a specified reference. This approach allows for the desired voltage source behavior to be minimally altered while safely limiting the current output.
format Preprint
id arxiv_https___arxiv_org_abs_2409_13890
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Safe Control of Grid-Interfacing Inverters with Current Magnitude Limits
Joswig-Jones, Trager
Zhang, Baosen
Systems and Control
Grid-interfacing inverters allow renewable resources to be connected to the electric grid and offer fast and programmable control responses. However, inverters are subject to significant physical constraints. One such constraint is a current magnitude limit required to protect semiconductor devices. While many current limiting methods are available, they can often unpredictably alter the behavior of the inverter control during overcurrent events leading to instability or poor performance. In this paper, we present a safety filter approach to limit the current magnitude of inverters controlled as voltage sources. The safety filter problem is formulated with a control barrier function constraint that encodes the current magnitude limit. To ensure feasibility of the problem, we prove the existence of a safe linear controller for a specified reference. This approach allows for the desired voltage source behavior to be minimally altered while safely limiting the current output.
title Safe Control of Grid-Interfacing Inverters with Current Magnitude Limits
topic Systems and Control
url https://arxiv.org/abs/2409.13890