Saved in:
Bibliographic Details
Main Authors: Muthusivarajan, Rajarajeswari, Celaya, Adrian, Farhat, Maguy, Talpur, Wasif, Langshaw, Holly, White, Victoria, Elliott, Andrew, Thrower, Sara, Schellingerhout, Dawid, Fuentes, David, Chung, Caroline
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2409.15177
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929511074889728
author Muthusivarajan, Rajarajeswari
Celaya, Adrian
Farhat, Maguy
Talpur, Wasif
Langshaw, Holly
White, Victoria
Elliott, Andrew
Thrower, Sara
Schellingerhout, Dawid
Fuentes, David
Chung, Caroline
author_facet Muthusivarajan, Rajarajeswari
Celaya, Adrian
Farhat, Maguy
Talpur, Wasif
Langshaw, Holly
White, Victoria
Elliott, Andrew
Thrower, Sara
Schellingerhout, Dawid
Fuentes, David
Chung, Caroline
contents Precise automated delineation of post-operative gross tumor volume in glioblastoma cases is challenging and time-consuming owing to the presence of edema and the deformed brain tissue resulting from the surgical tumor resection. To develop a model for automated delineation of post-operative gross tumor volumes in glioblastoma, we proposed a novel 3D double pocket U-Net architecture that has two parallel pocket U-Nets. Both U-Nets were trained simultaneously with two different subsets of MRI sequences and the output from the models was combined to do the final prediction. We strategically combined the MRI input sequences (T1, T2, T1C, FL) for model training to achieve improved segmentation accuracy. The dataset comprised 82 post-operative studies collected from 23 glioblastoma patients who underwent maximal safe tumor resection. All had gross tumor volume (GTV) segmentations performed by human experts, and these were used as a reference standard. The results of 3D double pocket U-Net were compared with baseline 3D pocket U-Net models and the ensemble of 3D pocket U-Net models. All the models were evaluated with fivefold cross-validation in terms of the Dice similarity coefficient and Hausdorff distance. Our proposed double U-Net model trained with input sequences [T1, T1C, FL + T2, T1C] achieved a better mean Dice score of 0.8585 and Hausdorff distance of 4.1942 compared to all the baseline models and ensemble models trained. The presence of infiltrating tumors and vasogenic edema in the post-operative MRI scans tends to reduce segmentation accuracy when considering the MRI sequences T1, T2, T1C, and FL together for model training. The double U-Net approach of combining subsets of the MRI sequences as distinct inputs for model training improves segmentation accuracy by 7% when compared with the conventional method of model training with all four sequences.
format Preprint
id arxiv_https___arxiv_org_abs_2409_15177
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Deep Learning-Based Automated Post-Operative Gross Tumor Volume Segmentation in Glioblastoma Patients
Muthusivarajan, Rajarajeswari
Celaya, Adrian
Farhat, Maguy
Talpur, Wasif
Langshaw, Holly
White, Victoria
Elliott, Andrew
Thrower, Sara
Schellingerhout, Dawid
Fuentes, David
Chung, Caroline
Image and Video Processing
Precise automated delineation of post-operative gross tumor volume in glioblastoma cases is challenging and time-consuming owing to the presence of edema and the deformed brain tissue resulting from the surgical tumor resection. To develop a model for automated delineation of post-operative gross tumor volumes in glioblastoma, we proposed a novel 3D double pocket U-Net architecture that has two parallel pocket U-Nets. Both U-Nets were trained simultaneously with two different subsets of MRI sequences and the output from the models was combined to do the final prediction. We strategically combined the MRI input sequences (T1, T2, T1C, FL) for model training to achieve improved segmentation accuracy. The dataset comprised 82 post-operative studies collected from 23 glioblastoma patients who underwent maximal safe tumor resection. All had gross tumor volume (GTV) segmentations performed by human experts, and these were used as a reference standard. The results of 3D double pocket U-Net were compared with baseline 3D pocket U-Net models and the ensemble of 3D pocket U-Net models. All the models were evaluated with fivefold cross-validation in terms of the Dice similarity coefficient and Hausdorff distance. Our proposed double U-Net model trained with input sequences [T1, T1C, FL + T2, T1C] achieved a better mean Dice score of 0.8585 and Hausdorff distance of 4.1942 compared to all the baseline models and ensemble models trained. The presence of infiltrating tumors and vasogenic edema in the post-operative MRI scans tends to reduce segmentation accuracy when considering the MRI sequences T1, T2, T1C, and FL together for model training. The double U-Net approach of combining subsets of the MRI sequences as distinct inputs for model training improves segmentation accuracy by 7% when compared with the conventional method of model training with all four sequences.
title Deep Learning-Based Automated Post-Operative Gross Tumor Volume Segmentation in Glioblastoma Patients
topic Image and Video Processing
url https://arxiv.org/abs/2409.15177