Uncertainty quantification in flow cytometry using a cell sorter

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Krishnaswamy-Usha, Amudhan, Cooksey, Gregory A., Patrone, Paul
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913517857144832
author Krishnaswamy-Usha, Amudhan
Cooksey, Gregory A.
Patrone, Paul
author_facet Krishnaswamy-Usha, Amudhan
Cooksey, Gregory A.
Patrone, Paul
contents In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise towards total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any 'spillover' is therefore due to instrument specific effects - we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how 'local affine transformations' let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
format Preprint
id arxiv_https___arxiv_org_abs_2409_17017
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Uncertainty quantification in flow cytometry using a cell sorter
Krishnaswamy-Usha, Amudhan
Cooksey, Gregory A.
Patrone, Paul
Instrumentation and Detectors
Quantitative Methods
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise towards total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any 'spillover' is therefore due to instrument specific effects - we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how 'local affine transformations' let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
title Uncertainty quantification in flow cytometry using a cell sorter
topic Instrumentation and Detectors
Quantitative Methods
url https://arxiv.org/abs/2409.17017