Black hole ring images from PSF structures

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Miyoshi, Makoto, Kato, Yoshiaki, Makino, Junichiro
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909327007154176
author Miyoshi, Makoto
Kato, Yoshiaki
Makino, Junichiro
author_facet Miyoshi, Makoto
Kato, Yoshiaki
Makino, Junichiro
contents Two critical aspects of radio interferometric imaging analysis are data calibration and deconvolution of the point spread function (PSF) structure. Both of these are particularly important for high-frequency observations using a VLBI network consisting of a small number of stations, such as those conducted by the Event Horizon Telescope (EHT). The Event Horizon Telescope Collaboration (EHTC) has presented images of ring-shaped black holes from observations of M 87 (d = 42 +- 3 muas)(EHTC2019a) and the Galactic Center (d = 51.8 +- 2.3 muas)(EHTC2022a). The ring structures seen in the EHTC images are consistent with the estimated shadow diameter of the black hole based on its mass and distance. However, these black hole ring sizes are also the same with the typical up and down spacings (e.g., the intervals between the main beam and nearby 1st-sidelobes) seen in the point spread function (PSF; dirty beam) for each observation. These facts suggest that the EHTC ring structures are artifacts derived from the shape of the PSFs rather than the intrinsic structure of the SMBHs in M 87 and the Galactic Center. The EHTC utilizes novel imaging techniques in addition to the standard CLEAN algorithm. The CLEAN method was designed for PSF shape deconvolution in mind, yet in practice, it may not always be able to completely remove the PSF shape. In the imaging analysis of data from interferometers with a small number of antennas like the EHT, it is crucial to assess the PSF shape and compare it with the imaging results. The novel imaging methods employed by the EHTC have not yet been fully evaluated for PSF deconvolution performance, and it is highly recommended that their performance in this regard be thoroughly examined. It is also important to investigate the data calibration capability, i.e., the ability to separate error noise from the observed data.
format Preprint
id arxiv_https___arxiv_org_abs_2409_17477
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Black hole ring images from PSF structures
Miyoshi, Makoto
Kato, Yoshiaki
Makino, Junichiro
Instrumentation and Methods for Astrophysics
Two critical aspects of radio interferometric imaging analysis are data calibration and deconvolution of the point spread function (PSF) structure. Both of these are particularly important for high-frequency observations using a VLBI network consisting of a small number of stations, such as those conducted by the Event Horizon Telescope (EHT). The Event Horizon Telescope Collaboration (EHTC) has presented images of ring-shaped black holes from observations of M 87 (d = 42 +- 3 muas)(EHTC2019a) and the Galactic Center (d = 51.8 +- 2.3 muas)(EHTC2022a). The ring structures seen in the EHTC images are consistent with the estimated shadow diameter of the black hole based on its mass and distance. However, these black hole ring sizes are also the same with the typical up and down spacings (e.g., the intervals between the main beam and nearby 1st-sidelobes) seen in the point spread function (PSF; dirty beam) for each observation. These facts suggest that the EHTC ring structures are artifacts derived from the shape of the PSFs rather than the intrinsic structure of the SMBHs in M 87 and the Galactic Center. The EHTC utilizes novel imaging techniques in addition to the standard CLEAN algorithm. The CLEAN method was designed for PSF shape deconvolution in mind, yet in practice, it may not always be able to completely remove the PSF shape. In the imaging analysis of data from interferometers with a small number of antennas like the EHT, it is crucial to assess the PSF shape and compare it with the imaging results. The novel imaging methods employed by the EHTC have not yet been fully evaluated for PSF deconvolution performance, and it is highly recommended that their performance in this regard be thoroughly examined. It is also important to investigate the data calibration capability, i.e., the ability to separate error noise from the observed data.
title Black hole ring images from PSF structures
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2409.17477