Initial performance assessment and calibration techniques of the production monolithic silicon pixel detector ASIC for the detection of electromagnetic showers of TeV energy in the FASER experiment at the LHC

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Kotitsa, Rafaella Eleni
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909328400711680
author Kotitsa, Rafaella Eleni
author_facet Kotitsa, Rafaella Eleni
contents The FASER experiment at the LHC aims to detect new, long-lived fundamental particles. A tungsten-silicon (W-Si) preshower detector is being developed to enhance the experiment's ability to distinguish between closely spaced photon pairs with energies on the order of TeV and separations as small as 200 \textmu m. This detector will use a monolithic silicon pixel sensor fabricated with 130 nm SiGe BiCMOS technology. Initial tests were conducted on the production ASIC, after evaluating the performance of the preproduction one. The first tests on the production ASIC indicate that the essential components of the monolithic silicon pixel detector are operating as expected. Two calibration methods were developed to reconstruct the charge of the FASER preshower detector, from the ASICs' ADC values.
format Preprint
id arxiv_https___arxiv_org_abs_2409_19030
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Initial performance assessment and calibration techniques of the production monolithic silicon pixel detector ASIC for the detection of electromagnetic showers of TeV energy in the FASER experiment at the LHC
Kotitsa, Rafaella Eleni
Instrumentation and Detectors
High Energy Physics - Experiment
The FASER experiment at the LHC aims to detect new, long-lived fundamental particles. A tungsten-silicon (W-Si) preshower detector is being developed to enhance the experiment's ability to distinguish between closely spaced photon pairs with energies on the order of TeV and separations as small as 200 \textmu m. This detector will use a monolithic silicon pixel sensor fabricated with 130 nm SiGe BiCMOS technology. Initial tests were conducted on the production ASIC, after evaluating the performance of the preproduction one. The first tests on the production ASIC indicate that the essential components of the monolithic silicon pixel detector are operating as expected. Two calibration methods were developed to reconstruct the charge of the FASER preshower detector, from the ASICs' ADC values.
title Initial performance assessment and calibration techniques of the production monolithic silicon pixel detector ASIC for the detection of electromagnetic showers of TeV energy in the FASER experiment at the LHC
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2409.19030