Calibration and Performance of the Upgraded ALICE Inner Tracking System

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Triolo, Andrea Sofia
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913522739314688
author Triolo, Andrea Sofia
author_facet Triolo, Andrea Sofia
contents The ALICE Experiment at the Large Hadron Collider (LHC) underwent a major upgrade during the Long Shutdown 2. Several subsystems have been improved, including the ALICE Inner Tracking System (ITS), which has been entirely replaced. The new pixel-only tracker (ITS2) consists of 7 layers of Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 27x29 $μ$m$^2$, with an intrinsic spatial resolution of 5 $μ$m. With 24120 sensors and 12.5 billion pixels, this detector covers an active area of about 10 m$^2$ and represents the largest application of the MAPS technology in a high-energy physics experiment to date. The most significant improvements introduced by the ITS2 to the ALICE experiment include a reduction in the impact parameter resolution to approximately 30 $μ$m in both the r$φ$ and z coordinates at a transverse momentum of 1 GeV/c. This is a factor of 3 improvement over the previous detector. Additionally, the standard ITS readout rate has been increased from 1 kHz to 67 kHz in Pb-Pb collisions and to 202 kHz in proton-proton collisions. To ensure stable operations and maintain high data quality a regular calibration is performed, which consists in establishing the charge threshold and the noisy channels of the detector. The ITS2 has been successfully commissioned for LHC Run3, and already operated during proton-proton and Pb-Pb collisions at LHC with excellent performance. This contribution gives an overview of the operational procedures required to maintain an optimal data quality, along with results obtained from calibration and the performance achieved during the LHC Run 3.
format Preprint
id arxiv_https___arxiv_org_abs_2409_19810
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Calibration and Performance of the Upgraded ALICE Inner Tracking System
Triolo, Andrea Sofia
Instrumentation and Detectors
High Energy Physics - Experiment
The ALICE Experiment at the Large Hadron Collider (LHC) underwent a major upgrade during the Long Shutdown 2. Several subsystems have been improved, including the ALICE Inner Tracking System (ITS), which has been entirely replaced. The new pixel-only tracker (ITS2) consists of 7 layers of Monolithic Active Pixel Sensors (MAPS) featuring a pixel size of 27x29 $μ$m$^2$, with an intrinsic spatial resolution of 5 $μ$m. With 24120 sensors and 12.5 billion pixels, this detector covers an active area of about 10 m$^2$ and represents the largest application of the MAPS technology in a high-energy physics experiment to date. The most significant improvements introduced by the ITS2 to the ALICE experiment include a reduction in the impact parameter resolution to approximately 30 $μ$m in both the r$φ$ and z coordinates at a transverse momentum of 1 GeV/c. This is a factor of 3 improvement over the previous detector. Additionally, the standard ITS readout rate has been increased from 1 kHz to 67 kHz in Pb-Pb collisions and to 202 kHz in proton-proton collisions. To ensure stable operations and maintain high data quality a regular calibration is performed, which consists in establishing the charge threshold and the noisy channels of the detector. The ITS2 has been successfully commissioned for LHC Run3, and already operated during proton-proton and Pb-Pb collisions at LHC with excellent performance. This contribution gives an overview of the operational procedures required to maintain an optimal data quality, along with results obtained from calibration and the performance achieved during the LHC Run 3.
title Calibration and Performance of the Upgraded ALICE Inner Tracking System
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2409.19810