Saved in:
Bibliographic Details
Main Author: Bossini, Edoardo
Format: Preprint
Published: 2024
Subjects:
Online Access:https://arxiv.org/abs/2409.20093
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915022715748352
author Bossini, Edoardo
author_facet Bossini, Edoardo
contents The TOTEM experiment at the LHC has produced a large set of measurements on diffractive processes and pp cross sections. A new detector, called nT2, has been designed to measure the inelastic scattering rate during the LHC special run of 2023. Due to the high radiation environment, the detector had to be installed in 10-20 minutes at most, then commissioned and operated after only few days. The detector, based on plastic scintillators read out by matrices of SiPMs, was designed with such constraints in mind. The front-end, DAQ and control electronics was developed with a fault tolerant architecture, moving as many functionalities as possible on a radiation tolerant SoC FPGA, hosting an integrated ARM controller. Here we will describe the nT2 detector and its read-out and control electronics. The detector was successfully operated during the special run: we will report the preliminary results on the detector performance.
format Preprint
id arxiv_https___arxiv_org_abs_2409_20093
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle The TOTEM nT2 detector: architecture, operation and performance
Bossini, Edoardo
High Energy Physics - Experiment
Instrumentation and Detectors
The TOTEM experiment at the LHC has produced a large set of measurements on diffractive processes and pp cross sections. A new detector, called nT2, has been designed to measure the inelastic scattering rate during the LHC special run of 2023. Due to the high radiation environment, the detector had to be installed in 10-20 minutes at most, then commissioned and operated after only few days. The detector, based on plastic scintillators read out by matrices of SiPMs, was designed with such constraints in mind. The front-end, DAQ and control electronics was developed with a fault tolerant architecture, moving as many functionalities as possible on a radiation tolerant SoC FPGA, hosting an integrated ARM controller. Here we will describe the nT2 detector and its read-out and control electronics. The detector was successfully operated during the special run: we will report the preliminary results on the detector performance.
title The TOTEM nT2 detector: architecture, operation and performance
topic High Energy Physics - Experiment
Instrumentation and Detectors
url https://arxiv.org/abs/2409.20093