Laboratory and beam-test performance study of a 55$~μ$m pitch iLGAD sensor bonded to a Timepix3 readout chip

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Svihra, Peter, Bates, Richard, Braach, Justus, Buschmann, Eric, Dannheim, Dominik, Maneuski, Dima, Moffat, Neil, Otarid, Younes
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916556694355968
author Svihra, Peter
Bates, Richard
Braach, Justus
Buschmann, Eric
Dannheim, Dominik
Maneuski, Dima
Moffat, Neil
Otarid, Younes
author_facet Svihra, Peter
Bates, Richard
Braach, Justus
Buschmann, Eric
Dannheim, Dominik
Maneuski, Dima
Moffat, Neil
Otarid, Younes
contents This contribution reports on characterisation results of a large-area (2$~\mathrm{cm}^2$) small pitch (55$~μ$m) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron Semiconductor Ltd with the goal to obtain good gain uniformity and maximise the fill-factor -- an issue present with standard small-pitch LGAD designs. We have conducted detailed performance evaluations using both X-ray calibrations and beam tests. An X-ray fluorescence setup has been used to obtain energy calibration and to identify the optimal operating settings of the new devices, whereas the extensive beam tests allowed for a detailed evaluation of the detector performance. The beam-tests were performed at the CERN SPS North Area H6 beamline, using a 120 GeV/c pion beam. The reference tracking and time-stamping is achieved by a Timepix3-based beam telescope setup. The results show a gain of around 5 with very good uniformity, measured across the whole gain area, as well as a hit time resolution down to 1.3 ns without correcting for the time-walk effects. Furthermore, it is shown that the gain opens the possibility of a good X-ray energy resolution down to 4.5 keV.
format Preprint
id arxiv_https___arxiv_org_abs_2409_20194
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Laboratory and beam-test performance study of a 55$~μ$m pitch iLGAD sensor bonded to a Timepix3 readout chip
Svihra, Peter
Bates, Richard
Braach, Justus
Buschmann, Eric
Dannheim, Dominik
Maneuski, Dima
Moffat, Neil
Otarid, Younes
Instrumentation and Detectors
This contribution reports on characterisation results of a large-area (2$~\mathrm{cm}^2$) small pitch (55$~μ$m) inverse Low-Gain Avalanche Detector (iLGAD), bonded to a Timepix3 readout chip. The ilGAD sensors were produced by Micron Semiconductor Ltd with the goal to obtain good gain uniformity and maximise the fill-factor -- an issue present with standard small-pitch LGAD designs. We have conducted detailed performance evaluations using both X-ray calibrations and beam tests. An X-ray fluorescence setup has been used to obtain energy calibration and to identify the optimal operating settings of the new devices, whereas the extensive beam tests allowed for a detailed evaluation of the detector performance. The beam-tests were performed at the CERN SPS North Area H6 beamline, using a 120 GeV/c pion beam. The reference tracking and time-stamping is achieved by a Timepix3-based beam telescope setup. The results show a gain of around 5 with very good uniformity, measured across the whole gain area, as well as a hit time resolution down to 1.3 ns without correcting for the time-walk effects. Furthermore, it is shown that the gain opens the possibility of a good X-ray energy resolution down to 4.5 keV.
title Laboratory and beam-test performance study of a 55$~μ$m pitch iLGAD sensor bonded to a Timepix3 readout chip
topic Instrumentation and Detectors
url https://arxiv.org/abs/2409.20194