Seamless Augmented Reality Integration in Arthroscopy: A Pipeline for Articular Reconstruction and Guidance

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Shu, Hongchao, Liu, Mingxu, Seenivasan, Lalithkumar, Gu, Suxi, Ku, Ping-Cheng, Knopf, Jonathan, Taylor, Russell, Unberath, Mathias
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914961350983680
author Shu, Hongchao
Liu, Mingxu
Seenivasan, Lalithkumar
Gu, Suxi
Ku, Ping-Cheng
Knopf, Jonathan
Taylor, Russell
Unberath, Mathias
author_facet Shu, Hongchao
Liu, Mingxu
Seenivasan, Lalithkumar
Gu, Suxi
Ku, Ping-Cheng
Knopf, Jonathan
Taylor, Russell
Unberath, Mathias
contents Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures. Aiming at enhancing intraoperative awareness, we present a robust pipeline that incorporates simultaneous localization and mapping, depth estimation, and 3D Gaussian splatting to realistically reconstruct intra-articular structures solely based on monocular arthroscope video. Extending 3D reconstruction to Augmented Reality (AR) applications, our solution offers AR assistance for articular notch measurement and annotation anchoring in a human-in-the-loop manner. Compared to traditional Structure-from-Motion and Neural Radiance Field-based methods, our pipeline achieves dense 3D reconstruction and competitive rendering fidelity with explicit 3D representation in 7 minutes on average. When evaluated on four phantom datasets, our method achieves RMSE = 2.21mm reconstruction error, PSNR = 32.86 and SSIM = 0.89 on average. Because our pipeline enables AR reconstruction and guidance directly from monocular arthroscopy without any additional data and/or hardware, our solution may hold the potential for enhancing intraoperative awareness and facilitating surgical precision in arthroscopy. Our AR measurement tool achieves accuracy within 1.59 +/- 1.81mm and the AR annotation tool achieves a mIoU of 0.721.
format Preprint
id arxiv_https___arxiv_org_abs_2410_00386
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Seamless Augmented Reality Integration in Arthroscopy: A Pipeline for Articular Reconstruction and Guidance
Shu, Hongchao
Liu, Mingxu
Seenivasan, Lalithkumar
Gu, Suxi
Ku, Ping-Cheng
Knopf, Jonathan
Taylor, Russell
Unberath, Mathias
Computer Vision and Pattern Recognition
Machine Learning
F.2.2; I.2.7
Arthroscopy is a minimally invasive surgical procedure used to diagnose and treat joint problems. The clinical workflow of arthroscopy typically involves inserting an arthroscope into the joint through a small incision, during which surgeons navigate and operate largely by relying on their visual assessment through the arthroscope. However, the arthroscope's restricted field of view and lack of depth perception pose challenges in navigating complex articular structures and achieving surgical precision during procedures. Aiming at enhancing intraoperative awareness, we present a robust pipeline that incorporates simultaneous localization and mapping, depth estimation, and 3D Gaussian splatting to realistically reconstruct intra-articular structures solely based on monocular arthroscope video. Extending 3D reconstruction to Augmented Reality (AR) applications, our solution offers AR assistance for articular notch measurement and annotation anchoring in a human-in-the-loop manner. Compared to traditional Structure-from-Motion and Neural Radiance Field-based methods, our pipeline achieves dense 3D reconstruction and competitive rendering fidelity with explicit 3D representation in 7 minutes on average. When evaluated on four phantom datasets, our method achieves RMSE = 2.21mm reconstruction error, PSNR = 32.86 and SSIM = 0.89 on average. Because our pipeline enables AR reconstruction and guidance directly from monocular arthroscopy without any additional data and/or hardware, our solution may hold the potential for enhancing intraoperative awareness and facilitating surgical precision in arthroscopy. Our AR measurement tool achieves accuracy within 1.59 +/- 1.81mm and the AR annotation tool achieves a mIoU of 0.721.
title Seamless Augmented Reality Integration in Arthroscopy: A Pipeline for Articular Reconstruction and Guidance
topic Computer Vision and Pattern Recognition
Machine Learning
F.2.2; I.2.7
url https://arxiv.org/abs/2410.00386