Development of the normalization method for the first large field-of-view plastic-based PET Modular scanner

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Coussat, A., Krzemien, W., Baran, J., Dulski, K., Klimaszewski, K., Raczyński, R. Y. Shopa L., Wiślicki, W.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910849055064064
author Coussat, A.
Krzemien, W.
Baran, J.
Dulski, K.
Klimaszewski, K.
Raczyński, R. Y. Shopa L.
Wiślicki, W.
author_facet Coussat, A.
Krzemien, W.
Baran, J.
Dulski, K.
Klimaszewski, K.
Raczyński, R. Y. Shopa L.
Wiślicki, W.
contents In positron emission tomography acquisition (PET), sensitivity along a line of response can vary due to crystal geometrical arrangements in the scanner and/or detector inefficiencies, leading to severe artefacts in the reconstructed image. To mitigate these effects, data must be corrected by a set of normalization coefficients applied to each line of response. The J-PET Modular scanner is a PET device made of 50 cm long plastic strips arranged axially, currently in operation at the Jagiellonian University in Kraków (Poland). We have implemented a normalization method for the large field-of-view plastic-based J-PET Modular scanner using the component-based approach. We estimated the geometric normalization factors for the J-PET Modular scanner using Monte Carlo simulations. We also analysed the effects of variations in detection efficiency. A dedicated cylindrical phantom was simulated to investigate the impact of various factors on image quality. The image quality was quantified in terms of radial and axial uniformity metrics, and the standard deviation to mean intensity ratio, determined for a set of image slices. Without normalization, reconstructions of a uniform cylinder exhibit artefacts. These artefacts were satisfactorily compensated using the normalization factors. Applying geometrical corrections lowers the non-uniformity of the image expressed as a standard deviation-to-mean ratio to a range between 5.5 % to 8.5 %. Computationally, the technique is straightforward to parallelize, making it time-efficient. Preliminary estimates suggest that the method is appropriate for use with long axial field-of-view scanners, such as the total-body J-PET, currently under development at the Jagiellonian University.
format Preprint
id arxiv_https___arxiv_org_abs_2410_00669
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Development of the normalization method for the first large field-of-view plastic-based PET Modular scanner
Coussat, A.
Krzemien, W.
Baran, J.
Dulski, K.
Klimaszewski, K.
Raczyński, R. Y. Shopa L.
Wiślicki, W.
Medical Physics
In positron emission tomography acquisition (PET), sensitivity along a line of response can vary due to crystal geometrical arrangements in the scanner and/or detector inefficiencies, leading to severe artefacts in the reconstructed image. To mitigate these effects, data must be corrected by a set of normalization coefficients applied to each line of response. The J-PET Modular scanner is a PET device made of 50 cm long plastic strips arranged axially, currently in operation at the Jagiellonian University in Kraków (Poland). We have implemented a normalization method for the large field-of-view plastic-based J-PET Modular scanner using the component-based approach. We estimated the geometric normalization factors for the J-PET Modular scanner using Monte Carlo simulations. We also analysed the effects of variations in detection efficiency. A dedicated cylindrical phantom was simulated to investigate the impact of various factors on image quality. The image quality was quantified in terms of radial and axial uniformity metrics, and the standard deviation to mean intensity ratio, determined for a set of image slices. Without normalization, reconstructions of a uniform cylinder exhibit artefacts. These artefacts were satisfactorily compensated using the normalization factors. Applying geometrical corrections lowers the non-uniformity of the image expressed as a standard deviation-to-mean ratio to a range between 5.5 % to 8.5 %. Computationally, the technique is straightforward to parallelize, making it time-efficient. Preliminary estimates suggest that the method is appropriate for use with long axial field-of-view scanners, such as the total-body J-PET, currently under development at the Jagiellonian University.
title Development of the normalization method for the first large field-of-view plastic-based PET Modular scanner
topic Medical Physics
url https://arxiv.org/abs/2410.00669