A novel ultrasonic device for monitoring implant condition

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Yazdkhasti, Amirhossein, Lloyd, Sophie, Schwab, Joseph H., Yu, Miao, Ghaednia, Hamid
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912055098867712
author Yazdkhasti, Amirhossein
Lloyd, Sophie
Schwab, Joseph H.
Yu, Miao
Ghaednia, Hamid
author_facet Yazdkhasti, Amirhossein
Lloyd, Sophie
Schwab, Joseph H.
Yu, Miao
Ghaednia, Hamid
contents Every year more than 2.3 million joint replacement is performed worldwide. Around 10% of these replacements fail those results in revisions at a cost of $8 billion per year. In particular patients younger than 55 years of age face higher risks of failure due to greater demand on their joints. The long-term failure of joint replacement such as implant loosening significantly decreases the life expectancy of replacement. One of the main challenges in understanding and treatment of implant loosening is lack of a low-cost screening device that can detect or predict loosening at very early stages. In this work we are proposing a novel method of screening implant condition via ultrasonic signals. In this method we are applying ultrasonic signals to the joint via several piezoresistive discs while reading signals with several other piezoresistive sensors. We are introducing a new approachin interpreting ultrasonic signals and we prove in a finite element environment that our method can be used to assess replacement condition. We show how our new concept can detect and distinguish between different implant fixation failure types sizes and even locate the position of the failure. We believe this work can be a foundation for development of a new generation of ultrasonic diagnosis wearable devices.
format Preprint
id arxiv_https___arxiv_org_abs_2410_00997
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A novel ultrasonic device for monitoring implant condition
Yazdkhasti, Amirhossein
Lloyd, Sophie
Schwab, Joseph H.
Yu, Miao
Ghaednia, Hamid
Signal Processing
Tissues and Organs
Every year more than 2.3 million joint replacement is performed worldwide. Around 10% of these replacements fail those results in revisions at a cost of $8 billion per year. In particular patients younger than 55 years of age face higher risks of failure due to greater demand on their joints. The long-term failure of joint replacement such as implant loosening significantly decreases the life expectancy of replacement. One of the main challenges in understanding and treatment of implant loosening is lack of a low-cost screening device that can detect or predict loosening at very early stages. In this work we are proposing a novel method of screening implant condition via ultrasonic signals. In this method we are applying ultrasonic signals to the joint via several piezoresistive discs while reading signals with several other piezoresistive sensors. We are introducing a new approachin interpreting ultrasonic signals and we prove in a finite element environment that our method can be used to assess replacement condition. We show how our new concept can detect and distinguish between different implant fixation failure types sizes and even locate the position of the failure. We believe this work can be a foundation for development of a new generation of ultrasonic diagnosis wearable devices.
title A novel ultrasonic device for monitoring implant condition
topic Signal Processing
Tissues and Organs
url https://arxiv.org/abs/2410.00997