Comparative in-silico study of drug release from intraocular implants for glaucoma treatment

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Pitafi, Umar, Chen, Tao, Yu-Wai-Man, Cynthia, Sebastia-Saez, Daniel
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866917093313609728
author Pitafi, Umar
Chen, Tao
Yu-Wai-Man, Cynthia
Sebastia-Saez, Daniel
author_facet Pitafi, Umar
Chen, Tao
Yu-Wai-Man, Cynthia
Sebastia-Saez, Daniel
contents Drug-releasing implants are gaining momentum in the treatment of glaucoma. However, they present several limitations, such as the inability to provide an even distribution of the drug in the trabecular meshwork. CFD simulations were used in this work to study the interplay between ocular fluid dynamics and drug diffusion to explore the options to achieve a homogeneous drug distribution in the target tissue. The analysis finds that thermal convective currents do not result in efficient mixing within the eye's anterior chamber. This results in highly localized drug delivery in the trabecular meshwork when using a gravity-placed cylindrical implant. Placing the implant in the posterior chamber results in improved mixing, although it presents the risk of therapeutical drugs being absorbed by the corneal endothelium instead of reaching the trabecular meshwork. Finally, a ring implant next to the trabecular meshwork is tested, which would give rise to a homogeneous concentration around the entirety of the trabecular meshwork. However, implanting a 360° ring with cylindrical cross-section next to the trabecular meshwork can entail significant surgical challenges, so the solution could consist of smaller cylindrical ring segments to attain a sufficient aqueous humour draining rate for each specific patient.
format Preprint
id arxiv_https___arxiv_org_abs_2410_01082
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Comparative in-silico study of drug release from intraocular implants for glaucoma treatment
Pitafi, Umar
Chen, Tao
Yu-Wai-Man, Cynthia
Sebastia-Saez, Daniel
Tissues and Organs
Drug-releasing implants are gaining momentum in the treatment of glaucoma. However, they present several limitations, such as the inability to provide an even distribution of the drug in the trabecular meshwork. CFD simulations were used in this work to study the interplay between ocular fluid dynamics and drug diffusion to explore the options to achieve a homogeneous drug distribution in the target tissue. The analysis finds that thermal convective currents do not result in efficient mixing within the eye's anterior chamber. This results in highly localized drug delivery in the trabecular meshwork when using a gravity-placed cylindrical implant. Placing the implant in the posterior chamber results in improved mixing, although it presents the risk of therapeutical drugs being absorbed by the corneal endothelium instead of reaching the trabecular meshwork. Finally, a ring implant next to the trabecular meshwork is tested, which would give rise to a homogeneous concentration around the entirety of the trabecular meshwork. However, implanting a 360° ring with cylindrical cross-section next to the trabecular meshwork can entail significant surgical challenges, so the solution could consist of smaller cylindrical ring segments to attain a sufficient aqueous humour draining rate for each specific patient.
title Comparative in-silico study of drug release from intraocular implants for glaucoma treatment
topic Tissues and Organs
url https://arxiv.org/abs/2410.01082