Customized calibration sources in the JUNO experiment

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Takenaka, Akira, Hui, Jiaqi, Li, Rui, Hao, Shuhua, Huang, Junting, Lai, Haojing, Li, Yuan, Liu, Jianglai, Meng, Yue, Qian, Zhicheng, Wang, Hao, Xiang, Ziqian, Yuan, Zhe, Yun, Youhui, Zhang, Feiyang, Zhang, Tao, Zhang, Yuanyuan
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917871554134016
author Takenaka, Akira
Hui, Jiaqi
Li, Rui
Hao, Shuhua
Huang, Junting
Lai, Haojing
Li, Yuan
Liu, Jianglai
Meng, Yue
Qian, Zhicheng
Wang, Hao
Xiang, Ziqian
Yuan, Zhe
Yun, Youhui
Zhang, Feiyang
Zhang, Tao
Zhang, Yuanyuan
author_facet Takenaka, Akira
Hui, Jiaqi
Li, Rui
Hao, Shuhua
Huang, Junting
Lai, Haojing
Li, Yuan
Liu, Jianglai
Meng, Yue
Qian, Zhicheng
Wang, Hao
Xiang, Ziqian
Yuan, Zhe
Yun, Youhui
Zhang, Feiyang
Zhang, Tao
Zhang, Yuanyuan
contents We customized a laser calibration system and four radioactive $γ$-ray calibration sources for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based neutrino detector. The laser source system was updated to realize the isotropic light emission timing within $\pm0.25$~nsec level and to allow the tuning of the laser intensity covering more than four orders of magnitude. In addition, methods to prepare four different radioactive sources ($^{18}{\rm F}$, $^{40}{\rm K}$, $^{226}{\rm Ra}$, and $^{241}{\rm Am}$), covering energies from O(10)~keV to O(1)~MeV, for the JUNO detector were established in this study. The radioactivity of each source and the risk of impurities leaking into the detector from the source were confirmed to meet the experimental requirements.
format Preprint
id arxiv_https___arxiv_org_abs_2410_01571
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Customized calibration sources in the JUNO experiment
Takenaka, Akira
Hui, Jiaqi
Li, Rui
Hao, Shuhua
Huang, Junting
Lai, Haojing
Li, Yuan
Liu, Jianglai
Meng, Yue
Qian, Zhicheng
Wang, Hao
Xiang, Ziqian
Yuan, Zhe
Yun, Youhui
Zhang, Feiyang
Zhang, Tao
Zhang, Yuanyuan
Instrumentation and Detectors
High Energy Physics - Experiment
We customized a laser calibration system and four radioactive $γ$-ray calibration sources for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based neutrino detector. The laser source system was updated to realize the isotropic light emission timing within $\pm0.25$~nsec level and to allow the tuning of the laser intensity covering more than four orders of magnitude. In addition, methods to prepare four different radioactive sources ($^{18}{\rm F}$, $^{40}{\rm K}$, $^{226}{\rm Ra}$, and $^{241}{\rm Am}$), covering energies from O(10)~keV to O(1)~MeV, for the JUNO detector were established in this study. The radioactivity of each source and the risk of impurities leaking into the detector from the source were confirmed to meet the experimental requirements.
title Customized calibration sources in the JUNO experiment
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2410.01571