Frequency-Dependent F-Numbers Suppress Grating Lobes and Improve the Lateral Resolution in Line-by-Line Scanning

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Schiffner, Martin F.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909450279845888
author Schiffner, Martin F.
author_facet Schiffner, Martin F.
contents Line-by-line scanning with linear arrays is a standard image formation method in clinical ultrasound. This method examines progressively a given region of interest by conducting focused pulse-echo measurements with dynamic transmit and receive apertures. Such apertures widen with the focal length as a function of a given F-number and improve the image quality by extending the depth of field (DOF) and suppressing grating lobes. Fixed F-numbers, however, limit the lateral resolution. Herein, frequency dependence of the F-number is incorporated into both the transmit and the receive focusing to widen the apertures for low frequencies and improve the lateral resolution. Frequency-dependent transmit and receive F-numbers are proposed. These F-numbers, which can be expressed in closed form, maximize the lateral resolution under constraints on the DOF and the grating lobes. A phantom experiment showed that the proposed F-numbers eliminate grating lobe artifacts and improve both image uniformity and contrast to a similar extent as fixed F-numbers. These metrics, compared to the usage of the full apertures, improved by up to 14.1 % and 8.3 %, respectively. The proposed F-numbers, however, improved the lateral resolution by up to 24 % compared to the fixed F-numbers.
format Preprint
id arxiv_https___arxiv_org_abs_2410_01593
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Frequency-Dependent F-Numbers Suppress Grating Lobes and Improve the Lateral Resolution in Line-by-Line Scanning
Schiffner, Martin F.
Medical Physics
Image and Video Processing
Signal Processing
Line-by-line scanning with linear arrays is a standard image formation method in clinical ultrasound. This method examines progressively a given region of interest by conducting focused pulse-echo measurements with dynamic transmit and receive apertures. Such apertures widen with the focal length as a function of a given F-number and improve the image quality by extending the depth of field (DOF) and suppressing grating lobes. Fixed F-numbers, however, limit the lateral resolution. Herein, frequency dependence of the F-number is incorporated into both the transmit and the receive focusing to widen the apertures for low frequencies and improve the lateral resolution. Frequency-dependent transmit and receive F-numbers are proposed. These F-numbers, which can be expressed in closed form, maximize the lateral resolution under constraints on the DOF and the grating lobes. A phantom experiment showed that the proposed F-numbers eliminate grating lobe artifacts and improve both image uniformity and contrast to a similar extent as fixed F-numbers. These metrics, compared to the usage of the full apertures, improved by up to 14.1 % and 8.3 %, respectively. The proposed F-numbers, however, improved the lateral resolution by up to 24 % compared to the fixed F-numbers.
title Frequency-Dependent F-Numbers Suppress Grating Lobes and Improve the Lateral Resolution in Line-by-Line Scanning
topic Medical Physics
Image and Video Processing
Signal Processing
url https://arxiv.org/abs/2410.01593