Neutral pressure measurement in TCV tokamak using ASDEX-type pressure gauges

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Sun, G., Reimerdes, H., Elaian, H., Baquero-Ruiz, M., Brown, B., Gospodarczyk, M., Noel, M., Tonello, E.
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911099687796736
author Sun, G.
Reimerdes, H.
Elaian, H.
Baquero-Ruiz, M.
Brown, B.
Gospodarczyk, M.
Noel, M.
Tonello, E.
author_facet Sun, G.
Reimerdes, H.
Elaian, H.
Baquero-Ruiz, M.
Brown, B.
Gospodarczyk, M.
Noel, M.
Tonello, E.
contents Probing the neutral gas distribution at the edge of magnetic confinement fusion devices is critical for plasma exhaust studies. In the TCV tokamak, a set of ASDEX-type hot ionization pressure gauges (APGs) has been installed for fast, in-situ measurements of the neutral pressure distribution in the TCV chamber. The APGs have been calibrated against baratron pressure gauges (BPGs) for pressures ranging from less than 1 mPa to several hundred mPa. A correction to account for the residual pressure in the pumped torus is proposed to improve the measurement accuracy. APG measurements in a series of plasma discharges with varied density ramp rates are analyzed and compared with the BPG pressure measurements. APG measurements feature a significantly faster time response and extend the BPG measurement range to lower pressures. Systematically higher neutral pressures measured with APGs compared to BPGs connected to the same TCV port, are attributed to the BPG's slower time response and a nonuniform neutral distribution in gauge ports during the plasma discharge. The initial APG operations in TCV have been proven successful, which validates the APG as an adequate pressure measurement technique for the upcoming TCV divertor upgrades.
format Preprint
id arxiv_https___arxiv_org_abs_2410_02933
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Neutral pressure measurement in TCV tokamak using ASDEX-type pressure gauges
Sun, G.
Reimerdes, H.
Elaian, H.
Baquero-Ruiz, M.
Brown, B.
Gospodarczyk, M.
Noel, M.
Tonello, E.
Plasma Physics
Probing the neutral gas distribution at the edge of magnetic confinement fusion devices is critical for plasma exhaust studies. In the TCV tokamak, a set of ASDEX-type hot ionization pressure gauges (APGs) has been installed for fast, in-situ measurements of the neutral pressure distribution in the TCV chamber. The APGs have been calibrated against baratron pressure gauges (BPGs) for pressures ranging from less than 1 mPa to several hundred mPa. A correction to account for the residual pressure in the pumped torus is proposed to improve the measurement accuracy. APG measurements in a series of plasma discharges with varied density ramp rates are analyzed and compared with the BPG pressure measurements. APG measurements feature a significantly faster time response and extend the BPG measurement range to lower pressures. Systematically higher neutral pressures measured with APGs compared to BPGs connected to the same TCV port, are attributed to the BPG's slower time response and a nonuniform neutral distribution in gauge ports during the plasma discharge. The initial APG operations in TCV have been proven successful, which validates the APG as an adequate pressure measurement technique for the upcoming TCV divertor upgrades.
title Neutral pressure measurement in TCV tokamak using ASDEX-type pressure gauges
topic Plasma Physics
url https://arxiv.org/abs/2410.02933