Energy calibration of GTM on ground

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Huang, Chien-You, Chang, Hsiang-Kuang, Lin, Chih-Hsun, Tsao, Che-Chih, Hu, Chin-Ping, Chang, Hao-Min, Chen, Yan-Fu, Feng, An-Hsuan, Huang, Yi-Wen, Lin, Tzu-Hsuan, Tsao, Yi-Ning, Wu, Chih-En, Wu, Chun-Wei
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866912062031003648
author Huang, Chien-You
Chang, Hsiang-Kuang
Lin, Chih-Hsun
Tsao, Che-Chih
Hu, Chin-Ping
Chang, Hao-Min
Chen, Yan-Fu
Feng, An-Hsuan
Huang, Yi-Wen
Lin, Tzu-Hsuan
Tsao, Yi-Ning
Wu, Chih-En
Wu, Chun-Wei
author_facet Huang, Chien-You
Chang, Hsiang-Kuang
Lin, Chih-Hsun
Tsao, Che-Chih
Hu, Chin-Ping
Chang, Hao-Min
Chen, Yan-Fu
Feng, An-Hsuan
Huang, Yi-Wen
Lin, Tzu-Hsuan
Tsao, Yi-Ning
Wu, Chih-En
Wu, Chun-Wei
contents The Gamma-ray Transients Monitor (GTM) on board the Formosat-8B (FS-8B) satellite is designed to detect and localize Gamma-Ray Bursts (GRBs). By utilizing 2+2 CITIROC chips to manipulate 4+4 detectors, which are composed of GAGG(Ce) scintillators coupled with Silicon Photomultipliers (SiPMs) and oriented in various directions to achieve all-sky coverage, the GRB saturation fluences of GTM in the 50 keV to 1 MeV range for Short GRBs (SGRBs) and Long GRBs (LGRBs) were estimated to be about $3.1 \times 10^{-4}$ and $5.0 \times 10^{-3}\ {\rm erg/cm^2}$, respectively, based on simulations. To precisely interpret the GTM readout signal in terms of energy, several measurements for isotope and gain calibration were conducted. Despite encountering issues with crosstalk and SiPM saturation effect in the data, the energy spectrum can still be recovered by appropriately discarding channel noise and mapping with the correct ADC-to-energy relation. This paper summarizes the energy resolution of GTM and the linear variations in the relationship between photon energy and readout signal. At 662 keV, the energy resolution is about 16 %. Also, it demonstrates that greater gain is achieved by increasing voltage or decreasing temperature.
format Preprint
id arxiv_https___arxiv_org_abs_2410_04827
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Energy calibration of GTM on ground
Huang, Chien-You
Chang, Hsiang-Kuang
Lin, Chih-Hsun
Tsao, Che-Chih
Hu, Chin-Ping
Chang, Hao-Min
Chen, Yan-Fu
Feng, An-Hsuan
Huang, Yi-Wen
Lin, Tzu-Hsuan
Tsao, Yi-Ning
Wu, Chih-En
Wu, Chun-Wei
Instrumentation and Methods for Astrophysics
The Gamma-ray Transients Monitor (GTM) on board the Formosat-8B (FS-8B) satellite is designed to detect and localize Gamma-Ray Bursts (GRBs). By utilizing 2+2 CITIROC chips to manipulate 4+4 detectors, which are composed of GAGG(Ce) scintillators coupled with Silicon Photomultipliers (SiPMs) and oriented in various directions to achieve all-sky coverage, the GRB saturation fluences of GTM in the 50 keV to 1 MeV range for Short GRBs (SGRBs) and Long GRBs (LGRBs) were estimated to be about $3.1 \times 10^{-4}$ and $5.0 \times 10^{-3}\ {\rm erg/cm^2}$, respectively, based on simulations. To precisely interpret the GTM readout signal in terms of energy, several measurements for isotope and gain calibration were conducted. Despite encountering issues with crosstalk and SiPM saturation effect in the data, the energy spectrum can still be recovered by appropriately discarding channel noise and mapping with the correct ADC-to-energy relation. This paper summarizes the energy resolution of GTM and the linear variations in the relationship between photon energy and readout signal. At 662 keV, the energy resolution is about 16 %. Also, it demonstrates that greater gain is achieved by increasing voltage or decreasing temperature.
title Energy calibration of GTM on ground
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2410.04827