Real-time cardiac cine MRI -- A comparison of a diffusion probabilistic model with alternative state-of-the-art image reconstruction techniques for undersampled spiral acquisitions

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Schad, Oliver, Heidenreich, Julius Frederik, Petri, Nils-Christian, Kleineisel, Jonas, Sauer, Simon, Bley, Thorsten, Nordbeck, Peter, Petritsch, Bernhard, Wech, Tobias
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916425283665920
author Schad, Oliver
Heidenreich, Julius Frederik
Petri, Nils-Christian
Kleineisel, Jonas
Sauer, Simon
Bley, Thorsten
Nordbeck, Peter
Petritsch, Bernhard
Wech, Tobias
author_facet Schad, Oliver
Heidenreich, Julius Frederik
Petri, Nils-Christian
Kleineisel, Jonas
Sauer, Simon
Bley, Thorsten
Nordbeck, Peter
Petritsch, Bernhard
Wech, Tobias
contents ECG-gated cine imaging in breath-hold enables high-quality diagnostics in most patients, arrhythmia and inability to hold breath, however, can severely corrupt outcomes. Real-time cardiac MRI in free-breathing leverages robust and faster investigations regardless of these confounding factors. With the need for sufficient acceleration, adequate reconstruction methods, which transfer data into high quality images, are required. Undersampled spiral real-time acquisitions in free-breathing were conducted in a study with 16 healthy volunteers and 5 patients. Image reconstructions were performed using a novel score-based diffusion model, as well as a variational network and different compressed sensing approaches. The techniques were compared by means of an expert reader study, by calculating scalar metrics and difference images with respect to a segmented reference, and by a Bland-Altman analysis of cardiac functional parameters. In participants with irregular RR-cycles, spiral real-time acquisitions showed superior image quality with respect to the clinical reference standard. Reconstructions using the diffusion model, the variational network and l1-wavelets offered an overall comparable image quality, however sharpness was slightly increased by the diffusion approach. While slightly larger ejection fractions for the real-time acquisitions were exhibited with a bias of 1.6% for healthy subjects, differences in the data acquisition procedure resulted in uncertainties of 7.4%. The proposed real-time technique enables free-breathing acquisitions of spatio-temporal images with high-quality, covering the entire heart in less than one minute. Evaluation of the ejection fractions using the segmented reference can be significantly corrupted due to arrhythmias and averaging effects. Prolonged inference times of the diffusion model represent the main obstacle to overcome for clinical translation.
format Preprint
id arxiv_https___arxiv_org_abs_2410_04843
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Real-time cardiac cine MRI -- A comparison of a diffusion probabilistic model with alternative state-of-the-art image reconstruction techniques for undersampled spiral acquisitions
Schad, Oliver
Heidenreich, Julius Frederik
Petri, Nils-Christian
Kleineisel, Jonas
Sauer, Simon
Bley, Thorsten
Nordbeck, Peter
Petritsch, Bernhard
Wech, Tobias
Medical Physics
Image and Video Processing
ECG-gated cine imaging in breath-hold enables high-quality diagnostics in most patients, arrhythmia and inability to hold breath, however, can severely corrupt outcomes. Real-time cardiac MRI in free-breathing leverages robust and faster investigations regardless of these confounding factors. With the need for sufficient acceleration, adequate reconstruction methods, which transfer data into high quality images, are required. Undersampled spiral real-time acquisitions in free-breathing were conducted in a study with 16 healthy volunteers and 5 patients. Image reconstructions were performed using a novel score-based diffusion model, as well as a variational network and different compressed sensing approaches. The techniques were compared by means of an expert reader study, by calculating scalar metrics and difference images with respect to a segmented reference, and by a Bland-Altman analysis of cardiac functional parameters. In participants with irregular RR-cycles, spiral real-time acquisitions showed superior image quality with respect to the clinical reference standard. Reconstructions using the diffusion model, the variational network and l1-wavelets offered an overall comparable image quality, however sharpness was slightly increased by the diffusion approach. While slightly larger ejection fractions for the real-time acquisitions were exhibited with a bias of 1.6% for healthy subjects, differences in the data acquisition procedure resulted in uncertainties of 7.4%. The proposed real-time technique enables free-breathing acquisitions of spatio-temporal images with high-quality, covering the entire heart in less than one minute. Evaluation of the ejection fractions using the segmented reference can be significantly corrupted due to arrhythmias and averaging effects. Prolonged inference times of the diffusion model represent the main obstacle to overcome for clinical translation.
title Real-time cardiac cine MRI -- A comparison of a diffusion probabilistic model with alternative state-of-the-art image reconstruction techniques for undersampled spiral acquisitions
topic Medical Physics
Image and Video Processing
url https://arxiv.org/abs/2410.04843