Design and Experimental Application of a Radon Diffusion Chamber for Determining Diffusion Coefficients in Membrane Materials

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Wu, Liang-Yu, Si, Lin, Wu, Yuan, Gao, Zhi-Xing, Heng, Yue-Kun, Li, Yuan, Liu, Jiang-Lai, Luo, Xiao-Lan, Ma, Fei, Meng, Yue, Qian, Xiao-Hui, Qian, Zhi-Cheng, Wang, Hao, Yun, You-Hui, Zhang, Gao-Feng, Zhao, Jie
Formato: Preprint
Publicado: 2024
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910924525273088
author Wu, Liang-Yu
Si, Lin
Wu, Yuan
Gao, Zhi-Xing
Heng, Yue-Kun
Li, Yuan
Liu, Jiang-Lai
Luo, Xiao-Lan
Ma, Fei
Meng, Yue
Qian, Xiao-Hui
Qian, Zhi-Cheng
Wang, Hao
Yun, You-Hui
Zhang, Gao-Feng
Zhao, Jie
author_facet Wu, Liang-Yu
Si, Lin
Wu, Yuan
Gao, Zhi-Xing
Heng, Yue-Kun
Li, Yuan
Liu, Jiang-Lai
Luo, Xiao-Lan
Ma, Fei
Meng, Yue
Qian, Xiao-Hui
Qian, Zhi-Cheng
Wang, Hao
Yun, You-Hui
Zhang, Gao-Feng
Zhao, Jie
contents In recent years, the issue of radon emanation and diffusion has become a critical concern for rare decay experiments, such as JUNO and PandaX-4T. This paper introduces a detector design featuring a symmetric radon detector cavity for the quantitative assessment of membrane materials' radon blocking capabilities. The performance of this design is evaluated through the application of Fick's Law and the diffusion equation considering material solubility. Our detector has completed measurements of radon diffusion coefficients for four types of membrane materials currently used in experiments, which also confirms the rationality of this detector design. The findings are instrumental in guiding the selection and evaluation of optimal materials for radon shielding to reduce radon background, contributing to boost sensitivities of rare event research.
format Preprint
id arxiv_https___arxiv_org_abs_2410_06054
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Design and Experimental Application of a Radon Diffusion Chamber for Determining Diffusion Coefficients in Membrane Materials
Wu, Liang-Yu
Si, Lin
Wu, Yuan
Gao, Zhi-Xing
Heng, Yue-Kun
Li, Yuan
Liu, Jiang-Lai
Luo, Xiao-Lan
Ma, Fei
Meng, Yue
Qian, Xiao-Hui
Qian, Zhi-Cheng
Wang, Hao
Yun, You-Hui
Zhang, Gao-Feng
Zhao, Jie
Instrumentation and Detectors
High Energy Physics - Experiment
In recent years, the issue of radon emanation and diffusion has become a critical concern for rare decay experiments, such as JUNO and PandaX-4T. This paper introduces a detector design featuring a symmetric radon detector cavity for the quantitative assessment of membrane materials' radon blocking capabilities. The performance of this design is evaluated through the application of Fick's Law and the diffusion equation considering material solubility. Our detector has completed measurements of radon diffusion coefficients for four types of membrane materials currently used in experiments, which also confirms the rationality of this detector design. The findings are instrumental in guiding the selection and evaluation of optimal materials for radon shielding to reduce radon background, contributing to boost sensitivities of rare event research.
title Design and Experimental Application of a Radon Diffusion Chamber for Determining Diffusion Coefficients in Membrane Materials
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2410.06054