Approaching the quantum limit of energy resolution in animal magnetoreception

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Kominis, I. K., Gkoudinakis, E.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929680582443008
author Kominis, I. K.
Gkoudinakis, E.
author_facet Kominis, I. K.
Gkoudinakis, E.
contents A large number of magnetic sensors, like superconducting quantum interference devices, optical pumping and nitrogen vacancy magnetometers, were shown to satisfy the energy resolution limit. This limit states that the magnetic sensitivity of the sensor, when translated into a product of energy with time, is bounded below by Planck's constant, hbar. This bound implies a fundamental limitation as to what can be achieved in magnetic sensing. Here we explore biological magnetometers, in particular three magnetoreception mechanisms thought to underly animals' geomagnetic field sensing: the radical-pair, the magnetite and the MagR mechanism. We address the question of how close these mechanisms approach the energy resolution limit. At the quantitative level, the utility of the energy resolution limit is that it informs the workings of magnetic sensing in model-independent ways, and thus can provide subtle consistency checks for theoretical models and estimated or measured parameter values, particularly needed in complex biological systems. At the qualitative level, the closer the energy resolution is to hbar, the more "quantum" is the sensor. This offers an alternative route towards understanding the quantum biology of magnetoreception. It also quantifies the room for improvement, illuminating what Nature has achieved, and stimulating the engineering of biomimetic sensors exceeding Nature's magnetic sensing performance.
format Preprint
id arxiv_https___arxiv_org_abs_2410_07186
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Approaching the quantum limit of energy resolution in animal magnetoreception
Kominis, I. K.
Gkoudinakis, E.
Biological Physics
Chemical Physics
Quantum Physics
A large number of magnetic sensors, like superconducting quantum interference devices, optical pumping and nitrogen vacancy magnetometers, were shown to satisfy the energy resolution limit. This limit states that the magnetic sensitivity of the sensor, when translated into a product of energy with time, is bounded below by Planck's constant, hbar. This bound implies a fundamental limitation as to what can be achieved in magnetic sensing. Here we explore biological magnetometers, in particular three magnetoreception mechanisms thought to underly animals' geomagnetic field sensing: the radical-pair, the magnetite and the MagR mechanism. We address the question of how close these mechanisms approach the energy resolution limit. At the quantitative level, the utility of the energy resolution limit is that it informs the workings of magnetic sensing in model-independent ways, and thus can provide subtle consistency checks for theoretical models and estimated or measured parameter values, particularly needed in complex biological systems. At the qualitative level, the closer the energy resolution is to hbar, the more "quantum" is the sensor. This offers an alternative route towards understanding the quantum biology of magnetoreception. It also quantifies the room for improvement, illuminating what Nature has achieved, and stimulating the engineering of biomimetic sensors exceeding Nature's magnetic sensing performance.
title Approaching the quantum limit of energy resolution in animal magnetoreception
topic Biological Physics
Chemical Physics
Quantum Physics
url https://arxiv.org/abs/2410.07186