Optimization of the sensitivity of a temperature sensor based on germanium-vacancy color center (GeV) in diamond

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Cojocaru, I. S., Soshenko, V. V., Bolshedvorskii, S. V., Davydov, V. A., Kulikova, L. F., Agafonov, V. N., Chernyavskiy, A., Smolyaninov, A. N., Sorokin, V. N., Kilin, S. Ya., Akimov, A. V.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913599958548480
author Cojocaru, I. S.
Soshenko, V. V.
Bolshedvorskii, S. V.
Davydov, V. A.
Kulikova, L. F.
Agafonov, V. N.
Chernyavskiy, A.
Smolyaninov, A. N.
Sorokin, V. N.
Kilin, S. Ya.
Akimov, A. V.
author_facet Cojocaru, I. S.
Soshenko, V. V.
Bolshedvorskii, S. V.
Davydov, V. A.
Kulikova, L. F.
Agafonov, V. N.
Chernyavskiy, A.
Smolyaninov, A. N.
Sorokin, V. N.
Kilin, S. Ya.
Akimov, A. V.
contents Temperature sensors based on the GeV color center in diamond are gaining considerable attention in both scientific and industrial fields. For widespread industrial adoption, however, these sensors need a design that is as simple and cost-effective as possible. The original sensor design relied on measuring the spectral characteristics of the zero-phonon line. Recently, a modified approach was introduced, which involves splitting the GeV emission with a dichroic mirror and determining temperature based on the ratio of the two resulting signals. In this analysis, we provide a detailed comparison of both methods. At room temperature, the two methods show comparable performance, with slight variations depending on component quality. However, at temperatures around 300 °C, the new method's performance is estimated to be nearly twice that of the original, provided optimal filter parameters are used. Additionally, the sensitivity of the new method remains roughly consistent with its performance at room temperature.
format Preprint
id arxiv_https___arxiv_org_abs_2410_07276
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Optimization of the sensitivity of a temperature sensor based on germanium-vacancy color center (GeV) in diamond
Cojocaru, I. S.
Soshenko, V. V.
Bolshedvorskii, S. V.
Davydov, V. A.
Kulikova, L. F.
Agafonov, V. N.
Chernyavskiy, A.
Smolyaninov, A. N.
Sorokin, V. N.
Kilin, S. Ya.
Akimov, A. V.
Instrumentation and Detectors
Quantum Physics
Temperature sensors based on the GeV color center in diamond are gaining considerable attention in both scientific and industrial fields. For widespread industrial adoption, however, these sensors need a design that is as simple and cost-effective as possible. The original sensor design relied on measuring the spectral characteristics of the zero-phonon line. Recently, a modified approach was introduced, which involves splitting the GeV emission with a dichroic mirror and determining temperature based on the ratio of the two resulting signals. In this analysis, we provide a detailed comparison of both methods. At room temperature, the two methods show comparable performance, with slight variations depending on component quality. However, at temperatures around 300 °C, the new method's performance is estimated to be nearly twice that of the original, provided optimal filter parameters are used. Additionally, the sensitivity of the new method remains roughly consistent with its performance at room temperature.
title Optimization of the sensitivity of a temperature sensor based on germanium-vacancy color center (GeV) in diamond
topic Instrumentation and Detectors
Quantum Physics
url https://arxiv.org/abs/2410.07276