Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes -- applications to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Rodriguez-Rivera, Jose A., Stock, Chris
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913540773773312
author Rodriguez-Rivera, Jose A.
Stock, Chris
author_facet Rodriguez-Rivera, Jose A.
Stock, Chris
contents The finite volume algorithm for absorption correction developed by Wunch and Prewitt is examined. This algorithm is based on the numerical integration of the transmission function where three-dimensional quadratic surfaces define the sample boundaries. The algorithm can also calculate the mean path length required for second-extinction calculations. We apply this method to the neutron inelastic scattering measurements of CeRhIn$_{5}$ using the Multi-Axis Crystal Spectrometer (MACS) at NIST. The algorithm has been expanded to correct the absorption of multiple coaligned samples. We show that this procedure can account for the angular-dependent absorption, and the technique can be used to correct data and plan experiments.
format Preprint
id arxiv_https___arxiv_org_abs_2410_08313
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes -- applications to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST
Rodriguez-Rivera, Jose A.
Stock, Chris
Materials Science
The finite volume algorithm for absorption correction developed by Wunch and Prewitt is examined. This algorithm is based on the numerical integration of the transmission function where three-dimensional quadratic surfaces define the sample boundaries. The algorithm can also calculate the mean path length required for second-extinction calculations. We apply this method to the neutron inelastic scattering measurements of CeRhIn$_{5}$ using the Multi-Axis Crystal Spectrometer (MACS) at NIST. The algorithm has been expanded to correct the absorption of multiple coaligned samples. We show that this procedure can account for the angular-dependent absorption, and the technique can be used to correct data and plan experiments.
title Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes -- applications to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST
topic Materials Science