Versatile Full-Field Optical Coherence Tomography with Adjustable Transmission-to-Reflection Ratio and Enhanced Signal-to-Noise Ratio

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Fan, Youlong, Hu, Qingye, Wang, Zhongping, Zhang, Zengming, Wei, Xiantao
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910652720742400
author Fan, Youlong
Hu, Qingye
Wang, Zhongping
Zhang, Zengming
Wei, Xiantao
author_facet Fan, Youlong
Hu, Qingye
Wang, Zhongping
Zhang, Zengming
Wei, Xiantao
contents Traditional full-field optical coherence tomography (FF-OCT) is effective for rapid cross-sectional imaging but often suffers from incoherent signals due to imbalanced light intensities between the sample and reference arms. While the high-throughput dark-field (HTDF) FF-OCT technique employs an asymmetric beamsplitter (BS) to achieve an asymmetric beam-splitting ratio and optimize the utilization of available light, the fixed beam-splitting ratio in the optical system limits HTDF FF-OCT to effectively measuring only specific types of samples with certain scattering intensities. To address this limitation, we propose a more versatile FF-OCT system with an adjustable transmission-to-reflection ratio. This system enables accurate measurement across a broader range of samples by optimizing the light source and finely tuning the polarization to achieve the ideal ratio for different materials. We also observed that both signal-to-noise ratio (SNR) and imaging depth are influenced by the beam-splitting ratio. By precisely adjusting the beam-splitting ratio, both SNR and imaging depth can be optimized to achieve their optimal values.
format Preprint
id arxiv_https___arxiv_org_abs_2410_12449
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Versatile Full-Field Optical Coherence Tomography with Adjustable Transmission-to-Reflection Ratio and Enhanced Signal-to-Noise Ratio
Fan, Youlong
Hu, Qingye
Wang, Zhongping
Zhang, Zengming
Wei, Xiantao
Optics
Traditional full-field optical coherence tomography (FF-OCT) is effective for rapid cross-sectional imaging but often suffers from incoherent signals due to imbalanced light intensities between the sample and reference arms. While the high-throughput dark-field (HTDF) FF-OCT technique employs an asymmetric beamsplitter (BS) to achieve an asymmetric beam-splitting ratio and optimize the utilization of available light, the fixed beam-splitting ratio in the optical system limits HTDF FF-OCT to effectively measuring only specific types of samples with certain scattering intensities. To address this limitation, we propose a more versatile FF-OCT system with an adjustable transmission-to-reflection ratio. This system enables accurate measurement across a broader range of samples by optimizing the light source and finely tuning the polarization to achieve the ideal ratio for different materials. We also observed that both signal-to-noise ratio (SNR) and imaging depth are influenced by the beam-splitting ratio. By precisely adjusting the beam-splitting ratio, both SNR and imaging depth can be optimized to achieve their optimal values.
title Versatile Full-Field Optical Coherence Tomography with Adjustable Transmission-to-Reflection Ratio and Enhanced Signal-to-Noise Ratio
topic Optics
url https://arxiv.org/abs/2410.12449