Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Giguère, Cloé, Hart, Alexander, Bateman, Joseph, Korysko, Pierre, Farabolini, Wilfrid, LeChasseur, Yoan, Bazalova-Carter, Magdalena, Beaulieu, Luc
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929546528292864
author Giguère, Cloé
Hart, Alexander
Bateman, Joseph
Korysko, Pierre
Farabolini, Wilfrid
LeChasseur, Yoan
Bazalova-Carter, Magdalena
Beaulieu, Luc
author_facet Giguère, Cloé
Hart, Alexander
Bateman, Joseph
Korysko, Pierre
Farabolini, Wilfrid
LeChasseur, Yoan
Bazalova-Carter, Magdalena
Beaulieu, Luc
contents The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR), making them a promising modality for delivering FLASH radiotherapy in the clinic. However, apart from suitable VHEE sources, clinical translation requires accurate dosimetry, which is challenging due to the limitation of standard dosimeters under UHDR. Water-equivalent and real-time plastic scintillation dosimeters (PSDs) may offer a solution. In this study, a 4-channel PSD, consisting of polystyrene-based BCF12 and Medscint proprietary scintillators, polyvinyltoluene (PVT)-based EJ-212 and a clear plastic fiber channel for Cherenkov subtraction was exposed to the 200 MeV VHEE UHDR beam at the CLEAR CERN facility. The Hyperscint RP200 platform was used to assess linearity to dose pulses of up to 90 Gy and dose rates up to 4.6x10$^9$ Gy/s, and to investigate radiation damage and recovery after dose accumulation of 37.2 kGy. While clear fiber response was linear across the entire dose range studied, light output saturated above ~50 Gy/pulse for scintillators. Despite radiation damage, linearity was preserved, though it resulted in a decrease of scintillator and clear fiber light output of <1.85 %/kGy and a shift in spectra towards longer wavelengths. Short-term recovery (<100h) of these changes was observed and depended on rest duration and accumulated dose. After long-term rest (<172 days), light output recovery was partial, with 6-22% of residual permanent damage remaining, while spectral recovery was complete. We showed that PSDs are sensitive to radiation damage, but maintain dose linearity even after accumulated dose of 37.2 kGy, and exhibit significant response recovery. This work highlights the potential of PSDs for dosimetry in UHDR conditions.
format Preprint
id arxiv_https___arxiv_org_abs_2410_12535
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility
Giguère, Cloé
Hart, Alexander
Bateman, Joseph
Korysko, Pierre
Farabolini, Wilfrid
LeChasseur, Yoan
Bazalova-Carter, Magdalena
Beaulieu, Luc
Medical Physics
Instrumentation and Detectors
The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR), making them a promising modality for delivering FLASH radiotherapy in the clinic. However, apart from suitable VHEE sources, clinical translation requires accurate dosimetry, which is challenging due to the limitation of standard dosimeters under UHDR. Water-equivalent and real-time plastic scintillation dosimeters (PSDs) may offer a solution. In this study, a 4-channel PSD, consisting of polystyrene-based BCF12 and Medscint proprietary scintillators, polyvinyltoluene (PVT)-based EJ-212 and a clear plastic fiber channel for Cherenkov subtraction was exposed to the 200 MeV VHEE UHDR beam at the CLEAR CERN facility. The Hyperscint RP200 platform was used to assess linearity to dose pulses of up to 90 Gy and dose rates up to 4.6x10$^9$ Gy/s, and to investigate radiation damage and recovery after dose accumulation of 37.2 kGy. While clear fiber response was linear across the entire dose range studied, light output saturated above ~50 Gy/pulse for scintillators. Despite radiation damage, linearity was preserved, though it resulted in a decrease of scintillator and clear fiber light output of <1.85 %/kGy and a shift in spectra towards longer wavelengths. Short-term recovery (<100h) of these changes was observed and depended on rest duration and accumulated dose. After long-term rest (<172 days), light output recovery was partial, with 6-22% of residual permanent damage remaining, while spectral recovery was complete. We showed that PSDs are sensitive to radiation damage, but maintain dose linearity even after accumulated dose of 37.2 kGy, and exhibit significant response recovery. This work highlights the potential of PSDs for dosimetry in UHDR conditions.
title Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility
topic Medical Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2410.12535