An Image-Guided Robotic System for Transcranial Magnetic Stimulation: System Development and Experimental Evaluation

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Liu, Yihao, Zhang, Jiaming, Ai, Letian, Tian, Jing, Sefati, Shahriar, Liu, Huan, Martin-Gomez, Alejandro, Kheradmand, Amir, Armand, Mehran
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866929653332049920
author Liu, Yihao
Zhang, Jiaming
Ai, Letian
Tian, Jing
Sefati, Shahriar
Liu, Huan
Martin-Gomez, Alejandro
Kheradmand, Amir
Armand, Mehran
author_facet Liu, Yihao
Zhang, Jiaming
Ai, Letian
Tian, Jing
Sefati, Shahriar
Liu, Huan
Martin-Gomez, Alejandro
Kheradmand, Amir
Armand, Mehran
contents Transcranial magnetic stimulation (TMS) is a noninvasive medical procedure that can modulate brain activity, and it is widely used in neuroscience and neurology research. Compared to manual operators, robots may improve the outcome of TMS due to their superior accuracy and repeatability. However, there has not been a widely accepted standard protocol for performing robotic TMS using fine-segmented brain images, resulting in arbitrary planned angles with respect to the true boundaries of the modulated cortex. Given that the recent study in TMS simulation suggests a noticeable difference in outcomes when using different anatomical details, cortical shape should play a more significant role in deciding the optimal TMS coil pose. In this work, we introduce an image-guided robotic system for TMS that focuses on (1) establishing standardized planning methods and heuristics to define a reference (true zero) for the coil poses and (2) solving the issue that the manual coil placement requires expert hand-eye coordination which often leading to low repeatability of the experiments. To validate the design of our robotic system, a phantom study and a preliminary human subject study were performed. Our results show that the robotic method can half the positional error and improve the rotational accuracy by up to two orders of magnitude. The accuracy is proven to be repeatable because the standard deviation of multiple trials is lowered by an order of magnitude. The improved actuation accuracy successfully translates to the TMS application, with a higher and more stable induced voltage in magnetic field sensors.
format Preprint
id arxiv_https___arxiv_org_abs_2410_15243
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle An Image-Guided Robotic System for Transcranial Magnetic Stimulation: System Development and Experimental Evaluation
Liu, Yihao
Zhang, Jiaming
Ai, Letian
Tian, Jing
Sefati, Shahriar
Liu, Huan
Martin-Gomez, Alejandro
Kheradmand, Amir
Armand, Mehran
Robotics
Transcranial magnetic stimulation (TMS) is a noninvasive medical procedure that can modulate brain activity, and it is widely used in neuroscience and neurology research. Compared to manual operators, robots may improve the outcome of TMS due to their superior accuracy and repeatability. However, there has not been a widely accepted standard protocol for performing robotic TMS using fine-segmented brain images, resulting in arbitrary planned angles with respect to the true boundaries of the modulated cortex. Given that the recent study in TMS simulation suggests a noticeable difference in outcomes when using different anatomical details, cortical shape should play a more significant role in deciding the optimal TMS coil pose. In this work, we introduce an image-guided robotic system for TMS that focuses on (1) establishing standardized planning methods and heuristics to define a reference (true zero) for the coil poses and (2) solving the issue that the manual coil placement requires expert hand-eye coordination which often leading to low repeatability of the experiments. To validate the design of our robotic system, a phantom study and a preliminary human subject study were performed. Our results show that the robotic method can half the positional error and improve the rotational accuracy by up to two orders of magnitude. The accuracy is proven to be repeatable because the standard deviation of multiple trials is lowered by an order of magnitude. The improved actuation accuracy successfully translates to the TMS application, with a higher and more stable induced voltage in magnetic field sensors.