Shot-noise limited, 10 MHz swept-source optical coherence tomography for retinal imaging

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Grelet, Sacha, Jimenez, Alejandro Martinez, Montague, Patrick B., Podoleanu, Adrian
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910658092597248
author Grelet, Sacha
Jimenez, Alejandro Martinez
Montague, Patrick B.
Podoleanu, Adrian
author_facet Grelet, Sacha
Jimenez, Alejandro Martinez
Montague, Patrick B.
Podoleanu, Adrian
contents Akinetic swept-sources are essential for high-speed optical coherence tomography (OCT) imaging. Time-stretched supercontinuum (TSSC) lasers have proven to be efficient for multi-MHz swept-sources. However, lack of low-noise broadband lasers and of large dispersion devices in the water low-absorption band at 1060 nm have limited the biomedical applications of TSSC lasers. In this letter, an approach to tune the wavelength around 1050 nm over 90 nm with low-noise at 10 MHz is presented. This is based on all-normal dispersion (ANDi) supercontinuum dynamics, and employs a long chirped fiber Bragg grating (CFBG) to time-stretch a broadband pulse with a duty cycle of 93 %. Retinal images are demonstrated, with a sensitivity of 84 dB - approaching the shot noise limit. We believe this high-speed low-noise swept-source will greatly promote the development of OCT techniques for biomedical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2410_15692
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Shot-noise limited, 10 MHz swept-source optical coherence tomography for retinal imaging
Grelet, Sacha
Jimenez, Alejandro Martinez
Montague, Patrick B.
Podoleanu, Adrian
Optics
Medical Physics
Akinetic swept-sources are essential for high-speed optical coherence tomography (OCT) imaging. Time-stretched supercontinuum (TSSC) lasers have proven to be efficient for multi-MHz swept-sources. However, lack of low-noise broadband lasers and of large dispersion devices in the water low-absorption band at 1060 nm have limited the biomedical applications of TSSC lasers. In this letter, an approach to tune the wavelength around 1050 nm over 90 nm with low-noise at 10 MHz is presented. This is based on all-normal dispersion (ANDi) supercontinuum dynamics, and employs a long chirped fiber Bragg grating (CFBG) to time-stretch a broadband pulse with a duty cycle of 93 %. Retinal images are demonstrated, with a sensitivity of 84 dB - approaching the shot noise limit. We believe this high-speed low-noise swept-source will greatly promote the development of OCT techniques for biomedical applications.
title Shot-noise limited, 10 MHz swept-source optical coherence tomography for retinal imaging
topic Optics
Medical Physics
url https://arxiv.org/abs/2410.15692