Salvato in:
Dettagli Bibliografici
Autori principali: Canales-Rodríguez, Erick J, Tax, Chantal M. W., Fischi-Gomez, Elda, Jones, Derek K., Thiran, Jean-Philippe, Rafael-Patiño, Jonathan
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:https://arxiv.org/abs/2410.18842
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866929711282651136
author Canales-Rodríguez, Erick J
Tax, Chantal M. W.
Fischi-Gomez, Elda
Jones, Derek K.
Thiran, Jean-Philippe
Rafael-Patiño, Jonathan
author_facet Canales-Rodríguez, Erick J
Tax, Chantal M. W.
Fischi-Gomez, Elda
Jones, Derek K.
Thiran, Jean-Philippe
Rafael-Patiño, Jonathan
contents Quantifying the myelin sheath radius of myelinated axons in vivo is important for understanding, diagnosing, and monitoring various neurological disorders. Despite advancements in diffusion MRI (dMRI) microstructure techniques, there are currently no models specifically designed to estimate myelin sheath radii. This proof-of-concept theoretical study presents two novel dMRI models that characterize the signal from water diffusion confined to cylindrical surfaces, approximating myelin water diffusion. We derive their spherical mean signals, eliminating fiber orientation and dispersion effects for convenience. These models are further extended to account for multiple concentric cylinders, mimicking the layered structure of myelin. Additionally, we introduce a method to convert histological distributions of axonal inner radii from the literature into myelin sheath radius distributions. We also derive analytical expressions to estimate the effective myelin sheath radius expected from these distributions. Monte Carlo (MC) simulations conducted in cylindrical and spiral geometries validate the models. These simulations demonstrate agreement with analytical predictions. Furthermore, we observe significant correlations between the effective radii derived from histological distributions and those obtained by fitting the dMRI signal to a single-cylinder model. These models may be integrated with existing multi-compartment dMRI techniques, opening the door to non-invasive in vivo assessments of myelin sheath radii. Such assessments would require MRI scanners equipped with strong diffusion gradients, allowing measurements with short echo times. Further work is required to validate the technique with real dMRI data and histological measurements.
format Preprint
id arxiv_https___arxiv_org_abs_2410_18842
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A diffusion MRI model for random walks confined on cylindrical surfaces: Towards non-invasive quantification of myelin sheath radius
Canales-Rodríguez, Erick J
Tax, Chantal M. W.
Fischi-Gomez, Elda
Jones, Derek K.
Thiran, Jean-Philippe
Rafael-Patiño, Jonathan
Medical Physics
Quantifying the myelin sheath radius of myelinated axons in vivo is important for understanding, diagnosing, and monitoring various neurological disorders. Despite advancements in diffusion MRI (dMRI) microstructure techniques, there are currently no models specifically designed to estimate myelin sheath radii. This proof-of-concept theoretical study presents two novel dMRI models that characterize the signal from water diffusion confined to cylindrical surfaces, approximating myelin water diffusion. We derive their spherical mean signals, eliminating fiber orientation and dispersion effects for convenience. These models are further extended to account for multiple concentric cylinders, mimicking the layered structure of myelin. Additionally, we introduce a method to convert histological distributions of axonal inner radii from the literature into myelin sheath radius distributions. We also derive analytical expressions to estimate the effective myelin sheath radius expected from these distributions. Monte Carlo (MC) simulations conducted in cylindrical and spiral geometries validate the models. These simulations demonstrate agreement with analytical predictions. Furthermore, we observe significant correlations between the effective radii derived from histological distributions and those obtained by fitting the dMRI signal to a single-cylinder model. These models may be integrated with existing multi-compartment dMRI techniques, opening the door to non-invasive in vivo assessments of myelin sheath radii. Such assessments would require MRI scanners equipped with strong diffusion gradients, allowing measurements with short echo times. Further work is required to validate the technique with real dMRI data and histological measurements.
title A diffusion MRI model for random walks confined on cylindrical surfaces: Towards non-invasive quantification of myelin sheath radius
topic Medical Physics
url https://arxiv.org/abs/2410.18842