Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Bošnjak, Domagoj, Schussnig, Richard, Ranftl, Sascha, Holzapfel, Gerhard A., Fries, Thomas-Peter
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915381031993344
author Bošnjak, Domagoj
Schussnig, Richard
Ranftl, Sascha
Holzapfel, Gerhard A.
Fries, Thomas-Peter
author_facet Bošnjak, Domagoj
Schussnig, Richard
Ranftl, Sascha
Holzapfel, Gerhard A.
Fries, Thomas-Peter
contents In the context of numerical simulations of the vascular system, local geometric uncertainties have not yet been examined in sufficient detail due to model complexity and the associated large numerical effort. Such uncertainties are related to geometric modeling errors resulting from computed tomography imaging, segmentation and meshing. This work presents a methodology to systematically induce local modifications and perform a sufficient number of blood flow simulations to draw statistically relevant conclusions on the most commonly employed quantities of interest, such as flow rates or wall shear stress. The surface of a structured hexahedral mesh of a patient-specific aorta is perturbed by displacement maps defined via Gaussian random fields to stochastically model the local uncertainty of the boundary. Three different cases are studied, with the mean perturbation magnitude of $0.25$, $0.5$ and $1.0~$mm. Valid, locally perturbed meshes are constructed via an elasticity operator that extends surface perturbations into the interior. Otherwise, identical incompressible flow problems are solved on these meshes, taking physiological boundary conditions and Carreau fluid parameters into account. Roughly $300\,000$ three-dimensional non-stationary blood flow simulations are performed for the three different perturbation cases to estimate the probability distributions of the quantities of interest. Convergence studies justify the spatial resolution of the employed meshes. Overall, the results suggest that moderate geometric perturbations result in reasonable engineering accuracy (relative errors in single-digit percentage range) of the quantities of interest, with higher sensitivity for gradient-related measures, noting that the observed errors are not negligible.
format Preprint
id arxiv_https___arxiv_org_abs_2410_19472
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics
Bošnjak, Domagoj
Schussnig, Richard
Ranftl, Sascha
Holzapfel, Gerhard A.
Fries, Thomas-Peter
Medical Physics
Computational Engineering, Finance, and Science
In the context of numerical simulations of the vascular system, local geometric uncertainties have not yet been examined in sufficient detail due to model complexity and the associated large numerical effort. Such uncertainties are related to geometric modeling errors resulting from computed tomography imaging, segmentation and meshing. This work presents a methodology to systematically induce local modifications and perform a sufficient number of blood flow simulations to draw statistically relevant conclusions on the most commonly employed quantities of interest, such as flow rates or wall shear stress. The surface of a structured hexahedral mesh of a patient-specific aorta is perturbed by displacement maps defined via Gaussian random fields to stochastically model the local uncertainty of the boundary. Three different cases are studied, with the mean perturbation magnitude of $0.25$, $0.5$ and $1.0~$mm. Valid, locally perturbed meshes are constructed via an elasticity operator that extends surface perturbations into the interior. Otherwise, identical incompressible flow problems are solved on these meshes, taking physiological boundary conditions and Carreau fluid parameters into account. Roughly $300\,000$ three-dimensional non-stationary blood flow simulations are performed for the three different perturbation cases to estimate the probability distributions of the quantities of interest. Convergence studies justify the spatial resolution of the employed meshes. Overall, the results suggest that moderate geometric perturbations result in reasonable engineering accuracy (relative errors in single-digit percentage range) of the quantities of interest, with higher sensitivity for gradient-related measures, noting that the observed errors are not negligible.
title Geometric Uncertainty of Patient-Specific Blood Vessels and its Impact on Aortic Hemodynamics
topic Medical Physics
Computational Engineering, Finance, and Science
url https://arxiv.org/abs/2410.19472