Denoising study of Fluoroscopic Images in real time tumor tracking System based on Statistical model of noise

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Yan, Yongxuan, Fujii, Fumitake, Shiinoki, Takehiro
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913569526775808
author Yan, Yongxuan
Fujii, Fumitake
Shiinoki, Takehiro
author_facet Yan, Yongxuan
Fujii, Fumitake
Shiinoki, Takehiro
contents This study investigates the noise characteristics of intraoperative X-ray fluoroscopic images acquired during real-time image-guided radiotherapy (IGRT), and presents a novel noise image generation method based on the identified noise amplitude and spatial probability patterns. Initially, noise-free digitally reconstructed radiographs (DRRs) were generated using patient CT data combined with projection algorithms and the spatial configuration of the real-time tumor tracking system. Based on the observed noise probability and amplitude distributions, noise was then added to these DRRs to create Dataset 1. As a control, Dataset 2 was generated by adding Gaussian noise with the same mean and variance as Dataset 1; however, the noise probability in Dataset 2 is independent of pixel location and pixel intensity. Both datasets were used to fine-tune a pre-trained SwinIR model with identical training parameters. Tests on phantom images containing real noise show that the SwinIR model trained with the proposed noise model dataset achieves superior denoising performance over the model trained with Gaussian noise and the model without transfer learning, with an average PSNR improvement of 1.45 dB. This study contributes to a deeper understanding of noise patterns in these fluoroscopic images and is crucial for enhancing image quality and the accuracy of real-time tumor tracking in radiotherapy.
format Preprint
id arxiv_https___arxiv_org_abs_2411_00199
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Denoising study of Fluoroscopic Images in real time tumor tracking System based on Statistical model of noise
Yan, Yongxuan
Fujii, Fumitake
Shiinoki, Takehiro
Medical Physics
This study investigates the noise characteristics of intraoperative X-ray fluoroscopic images acquired during real-time image-guided radiotherapy (IGRT), and presents a novel noise image generation method based on the identified noise amplitude and spatial probability patterns. Initially, noise-free digitally reconstructed radiographs (DRRs) were generated using patient CT data combined with projection algorithms and the spatial configuration of the real-time tumor tracking system. Based on the observed noise probability and amplitude distributions, noise was then added to these DRRs to create Dataset 1. As a control, Dataset 2 was generated by adding Gaussian noise with the same mean and variance as Dataset 1; however, the noise probability in Dataset 2 is independent of pixel location and pixel intensity. Both datasets were used to fine-tune a pre-trained SwinIR model with identical training parameters. Tests on phantom images containing real noise show that the SwinIR model trained with the proposed noise model dataset achieves superior denoising performance over the model trained with Gaussian noise and the model without transfer learning, with an average PSNR improvement of 1.45 dB. This study contributes to a deeper understanding of noise patterns in these fluoroscopic images and is crucial for enhancing image quality and the accuracy of real-time tumor tracking in radiotherapy.
title Denoising study of Fluoroscopic Images in real time tumor tracking System based on Statistical model of noise
topic Medical Physics
url https://arxiv.org/abs/2411.00199