A Method for Imaging the Ischemic Penumbra with MRI using IVIM

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Liu, Mira M., Saadat, Niloufar, Roth, Steven P., Niekrasz, Marek A., Giurcanu, Mihai, Shazeeb, Mohammed Salman, Carroll, Timothy J., Christoforidis, Gregory A.
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866913658220576768
author Liu, Mira M.
Saadat, Niloufar
Roth, Steven P.
Niekrasz, Marek A.
Giurcanu, Mihai
Shazeeb, Mohammed Salman
Carroll, Timothy J.
Christoforidis, Gregory A.
author_facet Liu, Mira M.
Saadat, Niloufar
Roth, Steven P.
Niekrasz, Marek A.
Giurcanu, Mihai
Shazeeb, Mohammed Salman
Carroll, Timothy J.
Christoforidis, Gregory A.
contents This work examines the hypothesis that intravoxel incoherent motion MRI (IVIM) can quantify local cerebral blood flow (qCBF), infarct volume, and define the ischemic penumbra for determination of the perfusion-diffusion mismatch (PWI/DWI) volume in a setting of acute ischemic stroke. Eight experiments were conducted in a pre-clinical middle cerebral artery occlusion (MCAO) model. IVIM and dynamic susceptibility contrast (DSC) imaging were acquired 2.5hr post-MCAO. IVIM was post-processed using software written in-house to produce parametric images of local qCBF, Water Transport Time (WTT), diffusion, and subsequently, PWI/DWI mismatch. These IVIM image parameters were compared with delay-and-dispersion-corrected local-AIF DSC perfusion image parameters including Tmax, qCBF, mean transit time (MTT), and mean diffusivity for DSC PWI/DWI mismatch. Final infarct volume was measured 4hrs post-occlusion. Early (2.5hr post-occlusion) DSC qCBF and IVIM qCBF in the diffusion negative MCA territory correlated strongly (slope=1.00, p=0.01,R2=0.69,Lins CCC=0.71), and both DSC and IVIM qCBF values negatively correlated with final infarct volume (R2=0.78,R2=0.61 respectively). The volume of hypoperfusion measured at 2.5 hours from DSC qCBF and from IVIM qCBF both predicted final infarct volume with good sensitivity and correlation (slope=2.08, R2=0.67, slope=2.50,R2=0.68 respectively). IVIM PWI/DWI ratio was correlated with infarct growth (R2=0.70) and WTT correlated with MTT (slope=0.82,R2=0.60). IVIM qCBF correlated strongly with local-AIF DSC qCBF and IVIM PWI/DWI correlated strongly with infarct growth. Both DSC and IVIM quantitative perfusion image acquired early after occlusion were able to predict final infarct volume, and IVIM simultaneous PWI/DWI ratio predicted infarct growth.
format Preprint
id arxiv_https___arxiv_org_abs_2411_00671
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A Method for Imaging the Ischemic Penumbra with MRI using IVIM
Liu, Mira M.
Saadat, Niloufar
Roth, Steven P.
Niekrasz, Marek A.
Giurcanu, Mihai
Shazeeb, Mohammed Salman
Carroll, Timothy J.
Christoforidis, Gregory A.
Medical Physics
This work examines the hypothesis that intravoxel incoherent motion MRI (IVIM) can quantify local cerebral blood flow (qCBF), infarct volume, and define the ischemic penumbra for determination of the perfusion-diffusion mismatch (PWI/DWI) volume in a setting of acute ischemic stroke. Eight experiments were conducted in a pre-clinical middle cerebral artery occlusion (MCAO) model. IVIM and dynamic susceptibility contrast (DSC) imaging were acquired 2.5hr post-MCAO. IVIM was post-processed using software written in-house to produce parametric images of local qCBF, Water Transport Time (WTT), diffusion, and subsequently, PWI/DWI mismatch. These IVIM image parameters were compared with delay-and-dispersion-corrected local-AIF DSC perfusion image parameters including Tmax, qCBF, mean transit time (MTT), and mean diffusivity for DSC PWI/DWI mismatch. Final infarct volume was measured 4hrs post-occlusion. Early (2.5hr post-occlusion) DSC qCBF and IVIM qCBF in the diffusion negative MCA territory correlated strongly (slope=1.00, p=0.01,R2=0.69,Lins CCC=0.71), and both DSC and IVIM qCBF values negatively correlated with final infarct volume (R2=0.78,R2=0.61 respectively). The volume of hypoperfusion measured at 2.5 hours from DSC qCBF and from IVIM qCBF both predicted final infarct volume with good sensitivity and correlation (slope=2.08, R2=0.67, slope=2.50,R2=0.68 respectively). IVIM PWI/DWI ratio was correlated with infarct growth (R2=0.70) and WTT correlated with MTT (slope=0.82,R2=0.60). IVIM qCBF correlated strongly with local-AIF DSC qCBF and IVIM PWI/DWI correlated strongly with infarct growth. Both DSC and IVIM quantitative perfusion image acquired early after occlusion were able to predict final infarct volume, and IVIM simultaneous PWI/DWI ratio predicted infarct growth.
title A Method for Imaging the Ischemic Penumbra with MRI using IVIM
topic Medical Physics
url https://arxiv.org/abs/2411.00671