Experimental demonstration of dark current mitigation by an over-inserted plug in a normal conducting VHF gun

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Wang, X. -H., Shu, G., Qian, H., Li, X., Liu, Z., Jiang, Z., Meng, H., Xing, C., Zhou, Q., Deng, H.
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913570720055296
author Wang, X. -H.
Shu, G.
Qian, H.
Li, X.
Liu, Z.
Jiang, Z.
Meng, H.
Xing, C.
Zhou, Q.
Deng, H.
author_facet Wang, X. -H.
Shu, G.
Qian, H.
Li, X.
Liu, Z.
Jiang, Z.
Meng, H.
Xing, C.
Zhou, Q.
Deng, H.
contents The room temperature continuous wave (CW) very-high-frequency (VHF) gun is one of the candidates for the electron gun of the high-repetition-rate free-electron lasers (FELs). The VHF gun operates with a cathode gradient of ~ 20 MV/m and an accelerating voltage of ~ 750 kV. The gun dark current emission leads to beam loss along the FEL machine, therefore is a critical parameter for the performance of the CW gun. In this paper, we presents a systematic study of the dark current reduction of the VHF gun, including cathode region optimizations, dark current tracking simulations and measurements. Over-inserted cathode plugs were tested in two VHF guns of different acceleration gap sizes, and both demonstrated significant dark current reduction ratios of more than two orders of magnitude.
format Preprint
id arxiv_https___arxiv_org_abs_2411_01754
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Experimental demonstration of dark current mitigation by an over-inserted plug in a normal conducting VHF gun
Wang, X. -H.
Shu, G.
Qian, H.
Li, X.
Liu, Z.
Jiang, Z.
Meng, H.
Xing, C.
Zhou, Q.
Deng, H.
Accelerator Physics
The room temperature continuous wave (CW) very-high-frequency (VHF) gun is one of the candidates for the electron gun of the high-repetition-rate free-electron lasers (FELs). The VHF gun operates with a cathode gradient of ~ 20 MV/m and an accelerating voltage of ~ 750 kV. The gun dark current emission leads to beam loss along the FEL machine, therefore is a critical parameter for the performance of the CW gun. In this paper, we presents a systematic study of the dark current reduction of the VHF gun, including cathode region optimizations, dark current tracking simulations and measurements. Over-inserted cathode plugs were tested in two VHF guns of different acceleration gap sizes, and both demonstrated significant dark current reduction ratios of more than two orders of magnitude.
title Experimental demonstration of dark current mitigation by an over-inserted plug in a normal conducting VHF gun
topic Accelerator Physics
url https://arxiv.org/abs/2411.01754