Rarefied xenon flow in orificed hollow cathodes

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Taunay, Pierre-Yves C. R., Villafana, Willca, Vinoth, Sangeeta P., Kaganovich, Igor, Khodak, Andrei
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909570876571648
author Taunay, Pierre-Yves C. R.
Villafana, Willca
Vinoth, Sangeeta P.
Kaganovich, Igor
Khodak, Andrei
author_facet Taunay, Pierre-Yves C. R.
Villafana, Willca
Vinoth, Sangeeta P.
Kaganovich, Igor
Khodak, Andrei
contents A parametric study is conducted to quantify the effect of the keeper electrode geometry on the neutral flow quantities within orificed hollow cathodes, prior to cathode ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry strongly influences the product between the pressure in the orifice-keeper region and the distance between cathode and keeper, $P_{ko}\cdot D_{ko}$, a key parameter for successful cathode ignition. A representative cathode equipped with a keeper is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature, and a parametric study is then conducted. Parameters include the cathode pressure-diameter in the range of 1-5 Torr-cm and the following geometric ratios: cathode orifice-to-cathode inner radii in the range of 0.1-0.7, keeper orifice-to-cathode orifice radii in the range of 1-5, and keeper distance-to-cathode-orifice diameter, in the range of 0.5-10. If both keeper and cathode have identical orifice radii, the flow remains subsonic in the cathode orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the cathode orifice-keeper region is, on average, 4% that of the upstream pressure value. The orifice-keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between the cathode orifice plate and the keeper plate, in agreement with literature data. Trends are explained through control-volume-based conservation laws. The ratio of ignition-to-nominal mass flow rates is found to be in the range of 9-120, with a most probable value of 40, in agreement with literature data. This suggests that heater-less cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 40.
format Preprint
id arxiv_https___arxiv_org_abs_2411_05090
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Rarefied xenon flow in orificed hollow cathodes
Taunay, Pierre-Yves C. R.
Villafana, Willca
Vinoth, Sangeeta P.
Kaganovich, Igor
Khodak, Andrei
Fluid Dynamics
Plasma Physics
A parametric study is conducted to quantify the effect of the keeper electrode geometry on the neutral flow quantities within orificed hollow cathodes, prior to cathode ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry strongly influences the product between the pressure in the orifice-keeper region and the distance between cathode and keeper, $P_{ko}\cdot D_{ko}$, a key parameter for successful cathode ignition. A representative cathode equipped with a keeper is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature, and a parametric study is then conducted. Parameters include the cathode pressure-diameter in the range of 1-5 Torr-cm and the following geometric ratios: cathode orifice-to-cathode inner radii in the range of 0.1-0.7, keeper orifice-to-cathode orifice radii in the range of 1-5, and keeper distance-to-cathode-orifice diameter, in the range of 0.5-10. If both keeper and cathode have identical orifice radii, the flow remains subsonic in the cathode orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the cathode orifice-keeper region is, on average, 4% that of the upstream pressure value. The orifice-keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between the cathode orifice plate and the keeper plate, in agreement with literature data. Trends are explained through control-volume-based conservation laws. The ratio of ignition-to-nominal mass flow rates is found to be in the range of 9-120, with a most probable value of 40, in agreement with literature data. This suggests that heater-less cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 40.
title Rarefied xenon flow in orificed hollow cathodes
topic Fluid Dynamics
Plasma Physics
url https://arxiv.org/abs/2411.05090