Benchmarking 3D multi-coil NC-PDNet MRI reconstruction

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Tanabene, Asma, Radhakrishna, Chaithya Giliyar, Massire, Aurélien, Nadar, Mariappan S., Ciuciu, Philippe
Format: Preprint
Publié: 2024
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866929585674780672
author Tanabene, Asma
Radhakrishna, Chaithya Giliyar
Massire, Aurélien
Nadar, Mariappan S.
Ciuciu, Philippe
author_facet Tanabene, Asma
Radhakrishna, Chaithya Giliyar
Massire, Aurélien
Nadar, Mariappan S.
Ciuciu, Philippe
contents Deep learning has shown great promise for MRI reconstruction from undersampled data, yet there is a lack of research on validating its performance in 3D parallel imaging acquisitions with non-Cartesian undersampling. In addition, the artifacts and the resulting image quality depend on the under-sampling pattern. To address this uncharted territory, we extend the Non-Cartesian Primal-Dual Network (NC-PDNet), a state-of-the-art unrolled neural network, to a 3D multi-coil setting. We evaluated the impact of channel-specific versus channel-agnostic training configurations and examined the effect of coil compression. Finally, we benchmark four distinct non-Cartesian undersampling patterns, with an acceleration factor of six, using the publicly available Calgary-Campinas dataset. Our results show that NC-PDNet trained on compressed data with varying input channel numbers achieves an average PSNR of 42.98 dB for 1 mm isotropic 32 channel whole-brain 3D reconstruction. With an inference time of 4.95sec and a GPU memory usage of 5.49 GB, our approach demonstrates significant potential for clinical research application.
format Preprint
id arxiv_https___arxiv_org_abs_2411_05883
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Benchmarking 3D multi-coil NC-PDNet MRI reconstruction
Tanabene, Asma
Radhakrishna, Chaithya Giliyar
Massire, Aurélien
Nadar, Mariappan S.
Ciuciu, Philippe
Image and Video Processing
Computer Vision and Pattern Recognition
Deep learning has shown great promise for MRI reconstruction from undersampled data, yet there is a lack of research on validating its performance in 3D parallel imaging acquisitions with non-Cartesian undersampling. In addition, the artifacts and the resulting image quality depend on the under-sampling pattern. To address this uncharted territory, we extend the Non-Cartesian Primal-Dual Network (NC-PDNet), a state-of-the-art unrolled neural network, to a 3D multi-coil setting. We evaluated the impact of channel-specific versus channel-agnostic training configurations and examined the effect of coil compression. Finally, we benchmark four distinct non-Cartesian undersampling patterns, with an acceleration factor of six, using the publicly available Calgary-Campinas dataset. Our results show that NC-PDNet trained on compressed data with varying input channel numbers achieves an average PSNR of 42.98 dB for 1 mm isotropic 32 channel whole-brain 3D reconstruction. With an inference time of 4.95sec and a GPU memory usage of 5.49 GB, our approach demonstrates significant potential for clinical research application.
title Benchmarking 3D multi-coil NC-PDNet MRI reconstruction
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2411.05883