An Exploration of Parallel Imaging System for Very-low Field (50mT) MRI Scanner
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2024
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866917164512968704 |
|---|---|
| author | Yang, Lei He, Wei Shen, Sheng He, Yucheng Wu, Jiamin Xu, Zheng |
| author_facet | Yang, Lei He, Wei Shen, Sheng He, Yucheng Wu, Jiamin Xu, Zheng |
| contents | Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique for high-field MRI should be tailored to apply here, considering the differences in the direction of the main magnetic field and the presence of noise. A VLF-specific PI algorithm and phased-array coil are proposed, marking the first application of PI in VLF MRI. Reconstruction quality is enhanced by denoising undersampled k-space data using a linear-prediction based Kalman filter. Subsequently, the denoised k-space data are nonlinearly mapped from the original space onto a high-dimensional feature space, utilizing a polynomial feature mapping defined nonlinear frame. Frame parameters are calculated using auto-calibration signals (ACS) from the center k-space, and missing phase-encoding lines in the original space are estimated using acquired lines in the feature space. An 8-channel phased-array coil, designed for a vertical main magnetic field, is decoupled using geometric overlap and a low input impedance (LII) preamplifier. Healthy volunteer head imaging experiments using the proposed PI technique exhibit the lowest mean-squared-error (MSE) value and the highest peak-signal-to-noise (PSNR) and structural similarity index (SSIM) values compared to two widely used PI methods. The proposed PI technique enables the VLF MRI scanner to achieve similar image quality and a 72.5% improvement in signal-to-noise ratio (SNR) compared to fully sampled images while requiring less than 50% of the scan time. We present a PI technique tailored for VLF MRI scanner for the first time, along with potential research direction to achieve greater reduction factor. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2411_07489 |
| institution | arXiv |
| publishDate | 2024 |
| record_format | arxiv |
| spellingShingle | An Exploration of Parallel Imaging System for Very-low Field (50mT) MRI Scanner Yang, Lei He, Wei Shen, Sheng He, Yucheng Wu, Jiamin Xu, Zheng Medical Physics Instrumentation and Detectors Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique for high-field MRI should be tailored to apply here, considering the differences in the direction of the main magnetic field and the presence of noise. A VLF-specific PI algorithm and phased-array coil are proposed, marking the first application of PI in VLF MRI. Reconstruction quality is enhanced by denoising undersampled k-space data using a linear-prediction based Kalman filter. Subsequently, the denoised k-space data are nonlinearly mapped from the original space onto a high-dimensional feature space, utilizing a polynomial feature mapping defined nonlinear frame. Frame parameters are calculated using auto-calibration signals (ACS) from the center k-space, and missing phase-encoding lines in the original space are estimated using acquired lines in the feature space. An 8-channel phased-array coil, designed for a vertical main magnetic field, is decoupled using geometric overlap and a low input impedance (LII) preamplifier. Healthy volunteer head imaging experiments using the proposed PI technique exhibit the lowest mean-squared-error (MSE) value and the highest peak-signal-to-noise (PSNR) and structural similarity index (SSIM) values compared to two widely used PI methods. The proposed PI technique enables the VLF MRI scanner to achieve similar image quality and a 72.5% improvement in signal-to-noise ratio (SNR) compared to fully sampled images while requiring less than 50% of the scan time. We present a PI technique tailored for VLF MRI scanner for the first time, along with potential research direction to achieve greater reduction factor. |
| title | An Exploration of Parallel Imaging System for Very-low Field (50mT) MRI Scanner |
| topic | Medical Physics Instrumentation and Detectors |
| url | https://arxiv.org/abs/2411.07489 |