Comparison of Geant4-DNA and RITRACKS/RITCARD: microdosimetry, nanodosimetry and DNA break predictions

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Levrague, Victor, Delorme, R., Roccia, Mathieu, Tran, Ngoc Hoang, Incerti, Sebastien, Beuve, Michael, Testa, Etienne, Plante, Ianik, Rahmanian, Shirin, Poignant, Floriane
Natura: Preprint
Pubblicazione: 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866915015567605760
author Levrague, Victor
Delorme, R.
Roccia, Mathieu
Tran, Ngoc Hoang
Incerti, Sebastien
Beuve, Michael
Testa, Etienne
Plante, Ianik
Rahmanian, Shirin
Poignant, Floriane
author_facet Levrague, Victor
Delorme, R.
Roccia, Mathieu
Tran, Ngoc Hoang
Incerti, Sebastien
Beuve, Michael
Testa, Etienne
Plante, Ianik
Rahmanian, Shirin
Poignant, Floriane
contents This work aims at investigating the impact of DNA geometry, compaction and calculation chain on DNA break and chromosome aberration predictions for high charge and energy (HZE) ions, using the Monte Carlo codes Geant4-DNA, RITRACKS and RITCARD. To ensure consistency of ion transport of both codes, we first compared microdosimetry and nanodosimetry spectra for different ions of interest in hadrontherapy and space research. The Rudd model was used for the transport of ions in both models. Developments were made in Geant4 (v11.2) to include periodic boundary conditions (PBC) to account for electron equilibrium in small targets. Excellent agreements were found for both microdosimetric and nanodosimetric spectra for all ion types, with and without PBC. Some discrepancies remain for low-energy deposition events, likely due to differences in electron interaction models. The latest results obtained using the newly available Geant4 example ``dsbandrepair'' will be presented and compared to DNA break predictions obtained with RITCARD.
format Preprint
id arxiv_https___arxiv_org_abs_2411_07670
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Comparison of Geant4-DNA and RITRACKS/RITCARD: microdosimetry, nanodosimetry and DNA break predictions
Levrague, Victor
Delorme, R.
Roccia, Mathieu
Tran, Ngoc Hoang
Incerti, Sebastien
Beuve, Michael
Testa, Etienne
Plante, Ianik
Rahmanian, Shirin
Poignant, Floriane
Medical Physics
This work aims at investigating the impact of DNA geometry, compaction and calculation chain on DNA break and chromosome aberration predictions for high charge and energy (HZE) ions, using the Monte Carlo codes Geant4-DNA, RITRACKS and RITCARD. To ensure consistency of ion transport of both codes, we first compared microdosimetry and nanodosimetry spectra for different ions of interest in hadrontherapy and space research. The Rudd model was used for the transport of ions in both models. Developments were made in Geant4 (v11.2) to include periodic boundary conditions (PBC) to account for electron equilibrium in small targets. Excellent agreements were found for both microdosimetric and nanodosimetric spectra for all ion types, with and without PBC. Some discrepancies remain for low-energy deposition events, likely due to differences in electron interaction models. The latest results obtained using the newly available Geant4 example ``dsbandrepair'' will be presented and compared to DNA break predictions obtained with RITCARD.
title Comparison of Geant4-DNA and RITRACKS/RITCARD: microdosimetry, nanodosimetry and DNA break predictions
topic Medical Physics
url https://arxiv.org/abs/2411.07670