PatchCTG: Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Khan, M. Jaleed, Vatish, Manu, Jones, Gabriel Davis
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866929589007155200
author Khan, M. Jaleed
Vatish, Manu
Jones, Gabriel Davis
author_facet Khan, M. Jaleed
Vatish, Manu
Jones, Gabriel Davis
contents Antepartum Cardiotocography (CTG) is vital for fetal health monitoring, but traditional methods like the Dawes-Redman system are often limited by high inter-observer variability, leading to inconsistent interpretations and potential misdiagnoses. This paper introduces PatchCTG, a transformer-based model specifically designed for CTG analysis, employing patch-based tokenisation, instance normalisation and channel-independent processing to capture essential local and global temporal dependencies within CTG signals. PatchCTG was evaluated on the Oxford Maternity (OXMAT) dataset, comprising over 20,000 CTG traces across diverse clinical outcomes after applying the inclusion and exclusion criteria. With extensive hyperparameter optimisation, PatchCTG achieved an AUC of 77%, with specificity of 88% and sensitivity of 57% at Youden's index threshold, demonstrating adaptability to various clinical needs. Testing across varying temporal thresholds showed robust predictive performance, particularly with finetuning on data closer to delivery, achieving a sensitivity of 52% and specificity of 88% for near-delivery cases. These findings suggest the potential of PatchCTG to enhance clinical decision-making in antepartum care by providing a reliable, objective tool for fetal health assessment. The source code is available at https://github.com/jaleedkhan/PatchCTG.
format Preprint
id arxiv_https___arxiv_org_abs_2411_07796
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle PatchCTG: Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring
Khan, M. Jaleed
Vatish, Manu
Jones, Gabriel Davis
Artificial Intelligence
Machine Learning
Antepartum Cardiotocography (CTG) is vital for fetal health monitoring, but traditional methods like the Dawes-Redman system are often limited by high inter-observer variability, leading to inconsistent interpretations and potential misdiagnoses. This paper introduces PatchCTG, a transformer-based model specifically designed for CTG analysis, employing patch-based tokenisation, instance normalisation and channel-independent processing to capture essential local and global temporal dependencies within CTG signals. PatchCTG was evaluated on the Oxford Maternity (OXMAT) dataset, comprising over 20,000 CTG traces across diverse clinical outcomes after applying the inclusion and exclusion criteria. With extensive hyperparameter optimisation, PatchCTG achieved an AUC of 77%, with specificity of 88% and sensitivity of 57% at Youden's index threshold, demonstrating adaptability to various clinical needs. Testing across varying temporal thresholds showed robust predictive performance, particularly with finetuning on data closer to delivery, achieving a sensitivity of 52% and specificity of 88% for near-delivery cases. These findings suggest the potential of PatchCTG to enhance clinical decision-making in antepartum care by providing a reliable, objective tool for fetal health assessment. The source code is available at https://github.com/jaleedkhan/PatchCTG.
title PatchCTG: Patch Cardiotocography Transformer for Antepartum Fetal Health Monitoring
topic Artificial Intelligence
Machine Learning
url https://arxiv.org/abs/2411.07796