A fast plastic scintillator for low intensity proton beam monitoring

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: André, Adélie, Hoarau, Christophe, Boursier, Yannick, Cherni, Afef, Dupont, Mathieu, Martel, Laurent Gallin, Martel, Marie-Laure Gallin, Garnier, Alicia, Hérault, Joel, Hofverberg, Johan-Petter, Kavrigin, Pavel, Morel, Christian, Muraz, Jean-François, Pinson, Maxime, Tripodo, Giovanni, Maneval, Daniel, Marcatili, Sara
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916479061983232
author André, Adélie
Hoarau, Christophe
Boursier, Yannick
Cherni, Afef
Dupont, Mathieu
Martel, Laurent Gallin
Martel, Marie-Laure Gallin
Garnier, Alicia
Hérault, Joel
Hofverberg, Johan-Petter
Kavrigin, Pavel
Morel, Christian
Muraz, Jean-François
Pinson, Maxime
Tripodo, Giovanni
Maneval, Daniel
Marcatili, Sara
author_facet André, Adélie
Hoarau, Christophe
Boursier, Yannick
Cherni, Afef
Dupont, Mathieu
Martel, Laurent Gallin
Martel, Marie-Laure Gallin
Garnier, Alicia
Hérault, Joel
Hofverberg, Johan-Petter
Kavrigin, Pavel
Morel, Christian
Muraz, Jean-François
Pinson, Maxime
Tripodo, Giovanni
Maneval, Daniel
Marcatili, Sara
contents In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25x25x1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of ~2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
format Preprint
id arxiv_https___arxiv_org_abs_2411_07877
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle A fast plastic scintillator for low intensity proton beam monitoring
André, Adélie
Hoarau, Christophe
Boursier, Yannick
Cherni, Afef
Dupont, Mathieu
Martel, Laurent Gallin
Martel, Marie-Laure Gallin
Garnier, Alicia
Hérault, Joel
Hofverberg, Johan-Petter
Kavrigin, Pavel
Morel, Christian
Muraz, Jean-François
Pinson, Maxime
Tripodo, Giovanni
Maneval, Daniel
Marcatili, Sara
Instrumentation and Detectors
Medical Physics
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25x25x1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of ~2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.
title A fast plastic scintillator for low intensity proton beam monitoring
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2411.07877