Non-Invasive Glucose Level Monitoring from PPG using a Hybrid CNN-GRU Deep Learning Network

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Soliman, Abdelrhman Y., Nor, Ahmed M., Fratu, Octavian, Halunga, Simona, Omer, Osama A., Mubark, Ahmed S.
Format: Preprint
Published: 2024
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866929594861355008
author Soliman, Abdelrhman Y.
Nor, Ahmed M.
Fratu, Octavian
Halunga, Simona
Omer, Osama A.
Mubark, Ahmed S.
author_facet Soliman, Abdelrhman Y.
Nor, Ahmed M.
Fratu, Octavian
Halunga, Simona
Omer, Osama A.
Mubark, Ahmed S.
contents Every year, humanity loses about 1.5 million persons due to diabetic disease. Therefore continuous monitoring of diabetes is highly needed, but the conventional approach, i.e., fingertip pricking, causes mental and physical pain to the patient. This work introduces painless and cheaper non-invasive blood glucose level monitoring, Exploiting the advancement and huge progress in deep learning to develop a hybrid convolution neural network (CNN) - gate recurrent unit (GRU) network to hit the targeted system, The proposed system deploys CNN for extracting spatial patterns in the photoplethysmogram (PPG) signal and GRU is used for detecting the temporal patterns. The performance of the proposed system achieves a Mean Absolute Error (MAE) of 2.96 mg/dL, a mean square error (MSE) of 15.53 mg/dL, a root mean square Error (RMSE) of 3.94 mg/dL, and a coefficient of determination ($R^2$ score) of 0.97 on the test dataset. According to the Clarke Error Grid analysis, 100% of points fall within the clinically acceptable zone (Class A)
format Preprint
id arxiv_https___arxiv_org_abs_2411_11094
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Non-Invasive Glucose Level Monitoring from PPG using a Hybrid CNN-GRU Deep Learning Network
Soliman, Abdelrhman Y.
Nor, Ahmed M.
Fratu, Octavian
Halunga, Simona
Omer, Osama A.
Mubark, Ahmed S.
Signal Processing
Every year, humanity loses about 1.5 million persons due to diabetic disease. Therefore continuous monitoring of diabetes is highly needed, but the conventional approach, i.e., fingertip pricking, causes mental and physical pain to the patient. This work introduces painless and cheaper non-invasive blood glucose level monitoring, Exploiting the advancement and huge progress in deep learning to develop a hybrid convolution neural network (CNN) - gate recurrent unit (GRU) network to hit the targeted system, The proposed system deploys CNN for extracting spatial patterns in the photoplethysmogram (PPG) signal and GRU is used for detecting the temporal patterns. The performance of the proposed system achieves a Mean Absolute Error (MAE) of 2.96 mg/dL, a mean square error (MSE) of 15.53 mg/dL, a root mean square Error (RMSE) of 3.94 mg/dL, and a coefficient of determination ($R^2$ score) of 0.97 on the test dataset. According to the Clarke Error Grid analysis, 100% of points fall within the clinically acceptable zone (Class A)
title Non-Invasive Glucose Level Monitoring from PPG using a Hybrid CNN-GRU Deep Learning Network
topic Signal Processing
url https://arxiv.org/abs/2411.11094