Non-unique water and contrast agent solutions in dual-energy CT

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Phillips, JP, Sidky, Emil Y., Terzioglu, Fatma, Reiser, Ingrid S., Bal, Guillaume, Pan, Xiaochuan
Format: Preprint
Veröffentlicht: 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866912127188467712
author Phillips, JP
Sidky, Emil Y.
Terzioglu, Fatma
Reiser, Ingrid S.
Bal, Guillaume
Pan, Xiaochuan
author_facet Phillips, JP
Sidky, Emil Y.
Terzioglu, Fatma
Reiser, Ingrid S.
Bal, Guillaume
Pan, Xiaochuan
contents The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity data for practical thickness ranges of water and contrast agent. Once existence is identified, non-unique solutions are found by simulating scan data and finding intensity contours with that intersect multiple times. With this process non-unique solutions are found for DECT setups scanning iodine and gadolinium, including setups using tube potentials in practical ranges. Non-unique solutions demonstrate a large range of differences and can result in significant discrepancies between recovered and true material mapping.
format Preprint
id arxiv_https___arxiv_org_abs_2411_12862
institution arXiv
publishDate 2024
record_format arxiv
spellingShingle Non-unique water and contrast agent solutions in dual-energy CT
Phillips, JP
Sidky, Emil Y.
Terzioglu, Fatma
Reiser, Ingrid S.
Bal, Guillaume
Pan, Xiaochuan
Medical Physics
The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity data for practical thickness ranges of water and contrast agent. Once existence is identified, non-unique solutions are found by simulating scan data and finding intensity contours with that intersect multiple times. With this process non-unique solutions are found for DECT setups scanning iodine and gadolinium, including setups using tube potentials in practical ranges. Non-unique solutions demonstrate a large range of differences and can result in significant discrepancies between recovered and true material mapping.
title Non-unique water and contrast agent solutions in dual-energy CT
topic Medical Physics
url https://arxiv.org/abs/2411.12862